< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=818233107660385&ev=PageView&noscript=1" />
X
立即发送您的询盘
快速报价

华泉中压发电机组参数有哪些?

I.Core answer

The voltage range of Huaquan medium-voltage generator sets spans from 3,300V (3.3电压) 至 13,800V (13.8电压), with power coverage ranging from 500kVA to 5,200kVA (约 400kW 至 4,200kW). 他们之中, 10.5电压 (10,500V) 是初级电压电平, 广泛应用于数据中心等场景, 医疗中心, 大型矿山, 和油田.

voltage levelTypical power range适用场景
3.3电压500-1000千瓦Small and medium-sized industrial projects
6.0电压1000-2000千瓦Mine and oil field parallel operation system
10.5电压 (main power)1000-3000千瓦数据中心, medical center, large-scale mine
13.8电压2000kW+Large-scale power stations, overseas general contracting

Huaquan Power reminds you: Huaquan provides customized solutions for a full range of medium and high-voltage generator sets ranging from 3kV to 13.8kV. Specific voltage levels and power can be customized according to project requirements.

II.Comparison between medium-voltage and low-voltage generator sets

The main differences between medium-voltage generator sets and conventional low-voltage (400电压/230V) units lie in voltage levels, current sizes, and transmission distances.

比较维度Huaquan medium-pressure unitHuaquan low-voltage unit
voltage level3.3kV~13.8kV400电压/230V
current magnitude小的 (1000kW→61.9A)Large (1000kW→1800A)
transmission distanceFar (up to tens of kilometers)Nearby (≤500 meters)
Line lossminimalSignificant (large I²R)
适用场景Long-distance power transmission, large centralized loadLocal power distribution, small and medium-sized loads
Typical Applications数据中心, mine, oil field, airport工厂, 住宅区, 建筑工地

Huaquan’s Advantages: Huaquan’s medium-voltage units adopt a high-voltage, low-current 设计, resulting in minimal power loss during power transmission, making them particularly suitable for long-distance transmission scenarios.

三、. Reference parameters for low-voltage units (comparative benchmark)

Although the search results do not directly provide a detailed parameter table for medium-voltage units, the technical parameters of Huaquan low-voltage units can serve as a reference benchmark for performance levels. Medium-voltage units will be upgraded accordingly in terms of voltage level and protection.

  1. Parameters of 200kW generator set
parameter itemHuaquan standard value
机组型号HQ200GF
输出功率200千瓦 / 250千伏安
rated voltage400电压/230V
输出电流360一个
功率因数0.8 (lagging)
rated frequency50赫兹
额定速度1500转速
Overall dimensions2950×1080×1680mm
unit weight2200千克
噪音 (at 7m)95分贝(一个)
Protection levelIP22
insulation classH level
Voltage regulation rateSteady state ≤±1%, transient state +20% 到 -15%
Frequency regulation rateSteady state ≤±1%, transient state +10% 到 -7%
  1. Parameters of 280kW generator set
parameter itemHuaquan standard value
机组型号HQ280GF
输出功率280千瓦 / 350千伏安
rated voltage400电压/230V
输出电流504一个
功率因数0.8 (lagging)
rated frequency50赫兹
额定速度1500转速
Overall dimensions3350×1300×2040mm
unit weight2500千克
噪音 (at 7m)95分贝(一个)
Protection levelIP22
insulation classH level
柴油机型号6LTAA9.5-G1(DK)
diesel engine powerRated power: 290千瓦 / 待机功率: 300千瓦
位移9.5L
  1. Parameters of 500kW generator set
parameter itemHuaquan standard value
机组型号HQ500GF
输出功率500千瓦 / 625千伏安
rated voltage400电压/230V
输出电流900一个
功率因数0.8 (lagging)
rated frequency50赫兹
额定速度1500转速
Overall dimensions3680×1550×1900mm
unit weight4650千克
噪音 (at 7m)95分贝(一个)
Protection levelIP22
insulation classLevel H
Generator modelHQF-500 (independently developed by Huaquan)
  1. Parameters of 700kW generator set
parameter itemHuaquan standard value
机组型号HQ700GF
输出功率700千瓦 / 875千伏安
rated voltage400电压/230V
输出电流1260一个
功率因数0.8 (lagging)
rated frequency50赫兹
额定速度1500转速
Overall dimensions4200×1500×1880mm
unit weight4650千克
噪音 (at 7m)95分贝(一个)
Protection levelIP22
insulation classH level
柴油机型号YC6C1020L-D20 (玉柴)
diesel engine powerRated power: 680千瓦 / 待机功率: 748千瓦
位移39.58L
  1. Parameters of 1250kW generator set
parameter itemHuaquan standard value
机组型号HQ1250GF
输出功率1250千瓦 / 1562.5千伏安
rated voltage400电压/230V
输出电流2250一个
功率因数0.8 (lagging)
rated frequency50赫兹
额定速度1500转速
Overall dimensions7000×2200×2300mm
unit weight9000千克
噪音 (at 7m)95分贝(一个)
Protection levelIP22
insulation classH level
柴油机型号KTA50-G38(CK)
  1. Parameters of 1400kW generator set
parameter itemHuaquan standard value
机组型号HQ1400GF
输出功率1400千瓦 / 1750千伏安
rated voltage400电压/230V
输出电流2520一个
功率因数0.8 (lagging)
rated frequency50赫兹
额定速度1500转速
噪音 (at 7m)95分贝(一个)
Protection levelIP22
insulation classH level
柴油机型号YC16VTD2270-D30 / YC12VC2270-D31
diesel engine powerRated power: 1520千瓦 / 待机功率: 1672千瓦
位移52.26L / 79.17L

IV.Core Technical Advantages of Huaquan Medium-Voltage Generator Sets

  1. Voltage accuracy
parameterHuaquan Standardmeaning
Steady-state voltage regulation≤±1%The output voltage remains stable over a long period with minimal fluctuation
Transient voltage regulation+20%~-15%The voltage recovers quickly when the load is suddenly applied or removed
Voltage stabilization time≤1 secondStabilizes quickly after loading

The above data is referenced from the technical parameters of Huaquan low-voltage units, and the performance standards for medium-voltage units are equivalent or higher

  1. Insulation and protection
parameterHuaquan Standardmeaning
insulation classH levelMaximum allowable temperature of 180℃, high temperature resistance, and long lifespan
Protection levelIP22 (open-shelf type)Protect against solid objects larger than 12mm and vertical water droplets
Advantages of H-grade insulationIt has a higher temperature resistance than Class F (155℃)Stronger overload capacity and longer lifespan
  1. Generator manufacturing standards
parameterHuaquan Standard
Motor TypeAll-copper brushless excitation synchronous generator
wiring methodThree-phase four-wire, Y connection
adjustment method调压器 (自动电压调节器)
Manufacturing StandardGB/T2820 standard
Meets the standardRelevant standards of YD/T502 and GJB

Huaquan generator sets are manufactured and tested in accordance with GB/T2820 standards, and can meet the requirements of industry standards such as YD/T502 and GJB

V.Applicable Scenarios of Medium-Voltage Generator Sets

  1. 数据中心
要求Huaquan solution
Power supply reliabilityHuaquan medium-voltage units have been applied in multiple data center projects
电压稳定性High voltage and low current, high voltage regulation accuracy, strong anti-harmonic capability
remote power supplyThe advantage is obvious when the distance between the data center and the generator set is relatively large
  1. Mines and oil fields
要求Huaquan solution
High-power power supplyThe standalone unit can reach 1250-1400kW, while the parallel operation can reach over MW level
Long-distance power transmission6.0kV/10.5kV output, with minimal transmission loss over distances of tens of kilometers
Adaptation to harsh environmentsThe medium-voltage units used in mines have been applied in multiple large-scale mining projects
  1. Medical centers, airports
要求Huaquan solution
应急电源Self-starting of medium-voltage units, with a response time of seconds in case of mains power interruption
high reliabilityHuaquan medium-voltage units can be applied to industries such as medical centers and airport power supply
Centralized power supplyOne medium-voltage unit can cover the entire campus/terminal building

Huaquan generator sets are widely used in 数据中心, mine emergencies, continuous power stations, national banks, communication markets, petroleum systems, medical systems, 大型工业, 及其他领域.

VI.Common Issues

Q1: Why is the voltage of Huaquan medium-voltage generator set 10.5kV?

一个: The rated voltage of a generator is typically 5% higher than the rated voltage of the power grid to compensate for voltage drops along the transmission lines. When the rated voltage of the power grid is 10kV, the rated voltage of the generator is designed to be 10.5kV. When the 10.5kV output reaches the user end through the transmission lines, the voltage drops to around 10kV, ensuring normal operation of the equipment.

Q2: How to choose between medium-voltage units and low-voltage units?

一个: Huaquan Power recommends referring to the following standards:

Your request推荐解决方案原因
Single unit power < 500 千瓦Low-voltage unit (400V)Low-voltage equipment is mature and cost-effective
The distance between the load and the generator is less than 500 米Low-voltage unit (400V)Line loss is acceptable
Single unit power > 1000 千瓦Medium-voltage unit (10.5电压)High voltage and low current, resulting in a more reasonable equipment capacity
The distance between the load and the generator is greater than 1000 米Medium-voltage unit (10.5电压)The loss of power transmission over long distances is small
Data center/Medical centerMedium-voltage unit (10.5电压)Centralized power supply, high voltage regulation accuracy
Multiple high-power units operating in parallelMedium-voltage unit (6kV/10.5kV)The parallel operation system is mature and has strong harmonic suppression capability

第三季度: Can Huaquan medium-voltage generator sets be customized?

一个可以。一个: 是的, Huaquan provides a comprehensive solution for the entire series of medium and high-voltage generator sets ranging from 3kV to 13.8kV. Specific voltage levels and power can be customized according to project requirements.

第四季度: What are the protection level and insulation level of the medium-voltage generator set?

一个: Huaquan’s medium-voltage 发电机 have a protection level of up to IP22 (open-frame type), while containerized units offer a higher protection level, allowing for outdoor all-weather use. The insulation level is Class H, with a maximum allowable temperature of 180℃.

📌总结: Quick Reference for Parameters of Huaquan Medium-Voltage Generator Sets

projectHuaquan Standard
voltage range3.3kV~13.8kV
Main voltage10.5电压
功率范围500kVA to 5,200kVA (约 400kW 至 4,200kW)
频率50赫兹
功率因数0.8 (lagging)
insulation classH level
Voltage regulation rateSteady state ≤±1%, transient state +20% 到 -15%
Frequency regulation rateSteady state ≤±1%, transient state +10% 到 -7%
Manufacturing StandardGB/T2820 (meets industry standards such as YD/T502 and GJB)
application field数据中心, mines, 油田, 卫生保健, communications, and large-scale industries

Core advantages of Huaquan Power’s medium-pressure units:

  1. Wide voltage range: full series from 3.3kV to 13.8kV, with power coverage from 500kVA to 5,200kVA
  2. High voltage and low current: low transmission loss, suitable for long-distance power supply
  3. High voltage regulation accuracy: voltage accuracy ≤±1%, strong harmonic suppression capability
  4. High manufacturing standards: Strictly adhering to the GB/T2820 standard and meeting specific industry requirements
  5. Rich application experience: numerous successful cases in fields such as data centers, mines, 油田, and healthcare

For more technical details on medium-voltage generator sets or to obtain a selection plan, 请联系华泉电力客服