I.Respuesta principal

The voltage range of Huaquan medium-voltage generator sets spans from 3,300V (3.3kV) a 13.800V (13.8kV), with power coverage ranging from 500kVA to 5,200kVA (approximately 400kW to 4,200kW). entre ellos, 10.5kV (10,500V) is the primary voltage level, widely used in scenarios such as data centers, medical centers, large mines, and oil fields.

voltage levelTypical power rangeEscenarios aplicables
3.3kV500-1000kilovatiosSmall and medium-sized industrial projects
6.0kV1000-2000kilovatiosMine and oil field parallel operation system
10.5kV (main power)1000-3000kilovatioscentro de datos, medical center, large-scale mine
13.8kV2000kilovatios+Large-scale power stations, overseas general contracting

Huaquan Power te recuerda: Huaquan provides customized solutions for a full range of medium and high-voltage generator sets ranging from 3kV to 13.8kV. Specific voltage levels and power can be customized according to project requirements.

II.Comparison between medium-voltage and low-voltage generator sets

The main differences between medium-voltage generator sets and conventional low-voltage (400V/230V) units lie in voltage levels, current sizes, and transmission distances.

dimensión comparativaHuaquan medium-pressure unitHuaquan low-voltage unit
voltage level3.3kV~13.8kV400V/230V
current magnitudePequeño (1000kW→61.9A)Large (1000kW→1800A)
transmission distanceFar (up to tens of kilometers)Nearby (≤500 meters)
Line lossminimalSignificant (large I²R)
Escenarios aplicablesLong-distance power transmission, large centralized loadLocal power distribution, small and medium-sized loads
Typical Applicationscentro de datos, mine, oil field, airportFábricas, zonas residenciales, sitios de construcción

Las ventajas de Huaquan: Huaquan’s medium-voltage units adopt a high-voltage, low-current diseño, resulting in minimal power loss during power transmission, making them particularly suitable for long-distance transmission scenarios.

III. Reference parameters for low-voltage units (comparative benchmark)

Although the search results do not directly provide a detailed parameter table for medium-voltage units, the technical parameters of Huaquan low-voltage units can serve as a reference benchmark for performance levels. Medium-voltage units will be upgraded accordingly in terms of voltage level and protection.

  1. Parameters of 200kW generator set
parameter itemHuaquan standard value
Modelo de unidadHQ200GF
potencia de salida200kilovatios / 250kVA
tensión nominal400V/230V
corriente de salida360A
Factor de potencia0.8 (lagging)
rated frequency50Hz
velocidad nominal1500rpm
Overall dimensions2950×1080×1680mm
unit weight2200kilos
Ruido (at 7m)95dB(A)
Protection levelIP22
insulation classH level
Voltage regulation rateSteady state ≤±1%, transient state +20% a -15%
Frequency regulation rateSteady state ≤±1%, transient state +10% a -7%
  1. Parameters of 280kW generator set
parameter itemHuaquan standard value
Modelo de unidadHQ280GF
potencia de salida280kilovatios / 350kVA
tensión nominal400V/230V
corriente de salida504A
factor de potencia0.8 (lagging)
rated frequency50Hz
velocidad nominal1500rpm
Overall dimensions3350×1300×2040mm
unit weight2500kilos
Ruido (at 7m)95dB(A)
Protection levelIP22
insulation classH level
Modelo de motor diésel6LTAA9.5-G1(DK)
diesel engine powerRated power: 290kilovatios / Energía en espera: 300kilovatios
desplazamiento9.5l
  1. Parameters of 500kW generator set
parameter itemHuaquan standard value
Modelo de unidadHQ500GF
potencia de salida500kilovatios / 625kVA
tensión nominal400V/230V
corriente de salida900A
factor de potencia0.8 (lagging)
rated frequency50Hz
velocidad nominal1500rpm
Overall dimensions3680×1550×1900mm
unit weight4650kilos
Ruido (at 7m)95dB(A)
Protection levelIP22
insulation classLevel H
Generator modelHQF-500 (independently developed by Huaquan)
  1. Parameters of 700kW generator set
parameter itemHuaquan standard value
Modelo de unidadHQ700GF
potencia de salida700kilovatios / 875kVA
tensión nominal400V/230V
corriente de salida1260A
factor de potencia0.8 (lagging)
rated frequency50Hz
velocidad nominal1500rpm
Overall dimensions4200×1500×1880mm
unit weight4650kilos
Ruido (at 7m)95dB(A)
Protection levelIP22
insulation classH level
Modelo de motor diéselYC6C1020L-D20 (Yuchai)
diesel engine powerRated power: 680kilovatios / Energía en espera: 748kilovatios
desplazamiento39.58l
  1. Parameters of 1250kW generator set
parameter itemHuaquan standard value
Modelo de unidadHQ1250GF
potencia de salida1250kilovatios / 1562.5kVA
tensión nominal400V/230V
corriente de salida2250A
factor de potencia0.8 (lagging)
rated frequency50Hz
velocidad nominal1500rpm
Overall dimensions7000×2200×2300mm
unit weight9000kilos
Ruido (at 7m)95dB(A)
Protection levelIP22
insulation classH level
Modelo de motor diéselKTA50-G38(CK)
  1. Parameters of 1400kW generator set
parameter itemHuaquan standard value
Modelo de unidadHQ1400GF
potencia de salida1400kilovatios / 1750kVA
tensión nominal400V/230V
corriente de salida2520A
factor de potencia0.8 (lagging)
rated frequency50Hz
velocidad nominal1500rpm
Ruido (at 7m)95dB(A)
Protection levelIP22
insulation classH level
Modelo de motor diéselYC16VTD2270-D30 / YC12VC2270-D31
diesel engine powerRated power: 1520kilovatios / Energía en espera: 1672kilovatios
desplazamiento52.26l / 79.17l

IV.Core Technical Advantages of Huaquan Medium-Voltage Generator Sets

  1. Voltage accuracy
parámetroHuaquan Standardmeaning
Steady-state voltage regulation≤±1%The output voltage remains stable over a long period with minimal fluctuation
Transient voltage regulation+20%~-15%The voltage recovers quickly when the load is suddenly applied or removed
Voltage stabilization time≤1 secondStabilizes quickly after loading

The above data is referenced from the technical parameters of Huaquan low-voltage units, and the performance standards for medium-voltage units are equivalent or higher

  1. Insulation and protection
parámetroHuaquan Standardmeaning
insulation classH levelMaximum allowable temperature of 180℃, high temperature resistance, y larga vida útil
Protection levelIP22 (open-shelf type)Protect against solid objects larger than 12mm and vertical water droplets
Advantages of H-grade insulationIt has a higher temperature resistance than Class F (155℃)Stronger overload capacity and longer lifespan
  1. Generator manufacturing standards
parámetroHuaquan Standard
Motor TypeAll-copper brushless excitation synchronous generator
wiring methodThree-phase four-wire, Y connection
adjustment methodAVR (Regulador de voltaje automático)
Manufacturing StandardGB/T2820 standard
Meets the standardRelevant standards of YD/T502 and GJB

Huaquan generator sets are manufactured and tested in accordance with GB/T2820 standards, and can meet the requirements of industry standards such as YD/T502 and GJB

V.Applicable Scenarios of Medium-Voltage Generator Sets

  1. centro de datos
demandaHuaquan solution
Power supply reliabilityHuaquan medium-voltage units have been applied in multiple data center projects
Estabilidad de voltajeHigh voltage and low current, high voltage regulation accuracy, strong anti-harmonic capability
remote power supplyThe advantage is obvious when the distance between the data center and the generator set is relatively large
  1. Mines and oil fields
demandaHuaquan solution
High-power power supplyThe standalone unit can reach 1250-1400kW, while the parallel operation can reach over MW level
Long-distance power transmission6.0kV/10.5kV output, with minimal transmission loss over distances of tens of kilometers
Adaptation to harsh environmentsThe medium-voltage units used in mines have been applied in multiple large-scale mining projects
  1. Medical centers, airports
demandaHuaquan solution
suministro de energía de emergenciaSelf-starting of medium-voltage units, with a response time of seconds in case of mains power interruption
alta confiabilidadHuaquan medium-voltage units can be applied to industries such as medical centers and airport power supply
Centralized power supplyOne medium-voltage unit can cover the entire campus/terminal building

Huaquan generator sets are widely used in centros de datos, mine emergencies, continuous power stations, national banks, communication markets, petroleum systems, medical systems, industrias a gran escala, y otros campos.

VI.Problemas comunes

Q1: Why is the voltage of Huaquan medium-voltage generator set 10.5kV?

A: The rated voltage of a generator is typically 5% higher than the rated voltage of the power grid to compensate for voltage drops along the transmission lines. When the rated voltage of the power grid is 10kV, the rated voltage of the generator is designed to be 10.5kV. When the 10.5kV output reaches the user end through the transmission lines, the voltage drops to around 10kV, ensuring normal operation of the equipment.

Q2: How to choose between medium-voltage units and low-voltage units?

A: Huaquan Power recommends referring to the following standards:

Your requestRecommended Solutionrazón
Single unit power < 500 kilovatiosLow-voltage unit (400V)Low-voltage equipment is mature and cost-effective
The distance between the load and the generator is less than 500 metrosLow-voltage unit (400V)Line loss is acceptable
Single unit power > 1000 kilovatiosMedium-voltage unit (10.5kV)High voltage and low current, resulting in a more reasonable equipment capacity
The distance between the load and the generator is greater than 1000 metrosMedium-voltage unit (10.5kV)The loss of power transmission over long distances is small
Data center/Medical centerMedium-voltage unit (10.5kV)Centralized power supply, high voltage regulation accuracy
Multiple high-power units operating in parallelMedium-voltage unit (6kV/10.5kV)The parallel operation system is mature and has strong harmonic suppression capability

Q3: Can Huaquan medium-voltage generator sets be customized?

A可以。A: Sí, Huaquan provides a comprehensive solution for the entire series of medium and high-voltage generator sets ranging from 3kV to 13.8kV. Specific voltage levels and power can be customized according to project requirements.

Q4: What are the protection level and insulation level of the medium-voltage generator set?

A: Huaquan’s medium-voltage Generadores have a protection level of up to IP22 (open-frame type), while containerized units offer a higher protection level, allowing for outdoor all-weather use. The insulation level is Class H, with a maximum allowable temperature of 180℃.

📌 Summary: Quick Reference for Parameters of Huaquan Medium-Voltage Generator Sets

projectHuaquan Standard
voltage range3.3kV~13.8kV
Main voltage10.5kV
rango de potencia500kVA to 5,200kVA (approximately 400kW to 4,200kW)
frecuencia50Hz
factor de potencia0.8 (lagging)
insulation classH level
Voltage regulation rateSteady state ≤±1%, transient state +20% a -15%
Frequency regulation rateSteady state ≤±1%, transient state +10% a -7%
Manufacturing StandardGB/T2820 (meets industry standards such as YD/T502 and GJB)
application fieldCentros de datos, minas, campos petroleros, cuidado de la salud, communications, and large-scale industries

Core advantages of Huaquan Power’s medium-pressure units:

  1. Wide voltage range: full series from 3.3kV to 13.8kV, with power coverage from 500kVA to 5,200kVA
  2. High voltage and low current: low transmission loss, suitable for long-distance power supply
  3. High voltage regulation accuracy: voltage accuracy ≤±1%, strong harmonic suppression capability
  4. High manufacturing standards: Strictly adhering to the GB/T2820 standard and meeting specific industry requirements
  5. Rich application experience: numerous successful cases in fields such as data centers, minas, campos petroleros, and healthcare

For more technical details on medium-voltage generator sets or to obtain a selection plan, please contact Huaquan Power’s customer service