If you are looking for a 50 kW diesel kragopwekker, you need reliable technical data to make the right decision. This guide provides complete specifications, fuel consumption data, pricing, and selection advice for 50 kW generator sets used in industrial, kommersiële, and standby applications.
Quick Specifications: 50 kW Diesel Generator
| Parameter | Spesifikasie |
|---|---|
| Gegradeerde krag | 50 kW |
| Gegradeerde krag (kVA) | 62.5 |
| Brandstof tipe | Diesel |
| Fuel Consumption @ 100% Laai | 12.5 L/h |
| Fuel Consumption @ 75% Laai | 9.8 L/h |
| Fuel Consumption @ 50% Laai | 7.2 L/h |
| Open Set Noise Level | 98 dB(A) |
| Silent Enclosure Noise | 65 dB(A) |
| Dimensions (L×B×H, m) | 2.2×0.9×1.4 |
| Gewig (kg) | 1,200 |
| Price Range (FOB) | $8,000 – $15,000 |
Need a precise quote for your specific configuration? contact us for a free customized proposal.
What Applications Use a 50 kW kragopwekker?
A 50 kW diesel generator is a versatile power solution that serves multiple industries and applications:
- Vervaardigingsaanlegte: Provides backup power for production lines, ensuring zero downtime during grid outages. A single 50 kW unit can support a mid-size factory with critical loads.
- Commercial Buildings: Powers HVAC systems, hysbakke, beligting, and IT infrastructure in office buildings, shopping centers, en hotelle.
- Healthcare Facilities: Serves as emergency backup for hospitals and clinics where power interruption is not an option. Must comply with NFPA 110 requirements for 10-second start. See our hospital generator oplossings.
- Datasentrums: Provides Tier III/IV backup power for server rooms and network operations centers. Explore our data center generator options for mission-critical facilities.
- Konstruksieterreine: Powers heavy equipment, beligting, and temporary facilities on remote job sites.
- Mining Operations: Supplies continuous power for extraction equipment, ventilasie, and camp facilities in remote mining locations.
Fuel Consumption Details
Understanding fuel consumption is critical for calculating operating costs. Die 50 kW diesel generator consumption varies significantly with load:
| Laai vlak | Brandstofverbruik (L/h) | Daaglikse koste (24h @ $1.2/L) |
|---|---|---|
| 100% (Standby) | 12.5 | $360 |
| 75% (Typical) | 9.8 | $282 |
| 50% (Low load) | 7.2 | $207 |
Belangrik: Running a generator below 30% load for extended periods causes “nat stapeling” — unburned fuel accumulates in the exhaust, reducing engine life. Always size your generator so the typical load is between 50-80% van gegradeerde kapasiteit.
Price Breakdown: What Affects the Cost?
The price of a 50 kW diesel generator ranges from $8,000 aan $15,000 (FOB), depending on several factors:
1. Enjin handelsmerk
The engine is 60-70% of the total cost. Premium brands cost more but offer better reliability and resale value:
- Cummins: Most popular globally, excellent parts availability, 5-10% premie
- Perkins: British engineering, widely used in Europe and Middle East
- PERSOON: German engineering, best for high-performance applications, 15-20% premie
- Weichai / Yuchai: Chinese engine brands, competitive pricing, growing global acceptance
2. Tipe omhulsel
- Oop stel: Lowest cost, requires dedicated generator room
- stille kragopwekker: +15-25% koste, reduces noise to 65 dB(A)
- containerized generator: +25-35% koste, weatherproof, selfoon, quick deployment
3. Alternator Brand
- Stamford / Leroy-Somer: Premium, best for non-linear loads
- Marathon / Mecc Alte: Good quality, competitive pricing
- Chinese brands (Nee, ens.): Budget-friendly, adequate for standard applications
4. Controller
- Deep Sea (DSE): Bedryfstandaard, betroubaar, easy to program
- ComAp: Advanced features, afstandmonitering, multi-unit sync
- SmartGen: Cost-effective Chinese brand, growing market share
How to Choose the Right 50 kW kragopwekker
Stap 1: Determine Your Power Requirement
List all the equipment you need to power simultaneously. Voeg by 20% headroom for motor starting surges and future expansion. A 50 kW generator is typically suitable for loads between 25-40 kW.
Stap 2: Choose Standby vs. Eerste krag
- Standby: Slegs noodrugsteun, runs less than 200 ure/jaar. The generator can output 100% gegradeerde krag.
- Prime: Deurlopende werking, lopies 8,000+ ure/jaar. De-rate by 10% (output is 90% van nominale krag).
Stap 3: Select the Enclosure
If noise is a concern (residential area, hospitaal, office building), choose a stille kragopwekker. If you need mobility or quick deployment, choose a containerized generator.
Stap 4: Verifieer brandstoftoevoer
A 50 kW diesel generator at 75% load consumes approximately 9.8 L/h. For 24-hour operation, you need a base tank of at least 235 liters. Plan for daily fuel delivery or install an external day tank.
Installasievereistes
Ventilasie
The generator room must provide adequate airflow for combustion and cooling. A 50 kW unit requires approximately 312 m³/h of ventilation air. Install intake louvers on the low wall and exhaust louvers on the high wall opposite the radiator.
Foundation
The foundation must support the static weight of 1,200 kg plus dynamic loads during operation. A reinforced concrete pad of at least 200mm thickness is recommended, with anti-vibration mounts between the generator and the pad.
Electrical Connection
Use an Outomatiese oordragskakelaar (ATS) to switch between grid and generator power. The ATS should be rated for the full load current and include time-delay features to prevent unnecessary starts during momentary outages.
Onderhoudskedule
Regular maintenance extends engine life and ensures reliable starting when you need it most:
| Interval | Taak |
|---|---|
| Daagliks | Gaan olievlak na, koelmiddel vlak, brandstof vlak, battery spanning |
| Weekliks | Run under load for 30 minute, kyk vir lekkasies |
| Maandeliks | Clean air filter, check belt tension, test safety shutdowns |
| Elke 250 ure | Change oil and oil filter, check valve clearance |
| Elke 500 ure | Replace fuel filter, clean fuel tank, check injector nozzles |
| Elke 1,000 ure | Adjust valve clearance, test alternator insulation, check control system |
| Elke 2,000 ure | Overhaul cylinder head, replace coolant, test alternator winding resistance |
For a detailed checklist, see our diesel generator maintenance schedule guide.
Gereelde Vrae
How much does a 50 kW diesel generator cost?
A 50 kW diesel generator costs between $8,000 en $15,000 (FOB), depending on engine brand, tipe omhulsel, and alternator selection. Kontak ons for a detailed quotation based on your specific requirements.
What is the fuel consumption of a 50 kW kragopwekker?
By 75% laai, a 50 kW diesel generator consumes approximately 9.8 L/h. Op volle vrag, consumption rises to 12.5 L/h.
How long can a 50 kW generator run continuously?
With proper fuel supply and maintenance, a prime-rated 50 kW generator can run continuously for 24-48 hours before needing an oil check. For extended operation, schedule brief shutdowns every 500 hours for oil and filter changes.
What size room do I need for a 50 kW kragopwekker?
The generator dimensions are approximately 2.2×0.9×1.4 meters. Laat ten minste toe 1 meter clearance on all sides for maintenance access, plus space for the radiator airflow and exhaust system.
Kan a 50 kW generator power a hospital?
Ja, a 50 kW generator is commonly used for hospital backup power. It must meet NFPA 110 requirements including 10-second start capability. See our hospital generator page for compliance details.
Need a 50 kW Generator for Your Project?
We are Huaquan Power, a professional generator manufacturer with 15+ jare se ondervinding. Ons 50 kW diesel Kragopwekkers are built for reliability, doeltreffendheid, and long service life.
- Free technical consultation and generator selection
- Customized solutions with full technical specifications
- Complete delivery, installation and after-sales support
- Global shipping with CE, ISO certifications
Two ways to reach us:
- E-pos: huaquan@huaquanpower.com (we reply within 24 ure)
- WhatsApp: +86 159 0536 0672
Special Offer: Tell us your “power requirement + application scenario”, and we will send you a free Generator Selection Report with recommended models, technical specs, and reference pricing.
Click here to request your free quote →
⚡ Explore Related Solutions
- 🏭 100kW Diesel Generator
- 🏭 500kW Diesel Generator
- 🏭 1000kW Diesel Generator
- 🏭 500kW YC Diesel Generator
- 🔧 KMS (Cummins/Doosan) Reeks
- 🏥 Data Center Generator Solutions
- 🏥 Draagbare kragopwekker
💡 Need a customized solution? Contact our engineering team for project-specific recommendations.