If you are looking for a 2000 kW diesel kragopwekker, you need reliable technical data to make the right decision. This guide provides complete specifications, fuel consumption data, pricing, and selection advice for 2000 kW generator sets used in industrial, kommersiële, and standby applications.
Quick Specifications: 2000 kW Diesel Generator
| Parameter | Spesifikasie |
|---|---|
| Gegradeerde krag | 2000 kW |
| Gegradeerde krag (kVA) | 2500 |
| Brandstof tipe | Diesel |
| Fuel Consumption @ 100% Laai | 480 L/h |
| Fuel Consumption @ 75% Laai | 380 L/h |
| Fuel Consumption @ 50% Laai | 280 L/h |
| Open Set Noise Level | 120 dB(A) |
| Silent Enclosure Noise | 78 dB(A) |
| Dimensions (L×B×H, m) | 7.0×2.4×3.0 |
| Gewig (kg) | 25,000 |
| Price Range (FOB) | $250,000 – $450,000 |
Need a precise quote for your specific configuration? contact us for a free customized proposal.
What Applications Use a 2000 kW kragopwekker?
A 2000 kW diesel generator is a versatile power solution that serves multiple industries and applications:
- Vervaardigingsaanlegte: Provides backup power for production lines, ensuring zero downtime during grid outages. A single 2000 kW unit can support a mid-size factory with critical loads.
- Commercial Buildings: Powers HVAC systems, hysbakke, beligting, and IT infrastructure in office buildings, shopping centers, en hotelle.
- Healthcare Facilities: Serves as emergency backup for hospitals and clinics where power interruption is not an option. Must comply with NFPA 110 requirements for 10-second start. See our hospital generator oplossings.
- Datasentrums: Provides Tier III/IV backup power for server rooms and network operations centers. Explore our data center generator options for mission-critical facilities.
- Konstruksieterreine: Powers heavy equipment, beligting, and temporary facilities on remote job sites.
- Mining Operations: Supplies continuous power for extraction equipment, ventilasie, and camp facilities in remote mining locations.
Fuel Consumption Details
Understanding fuel consumption is critical for calculating operating costs. Die 2000 kW diesel generator consumption varies significantly with load:
| Laai vlak | Brandstofverbruik (L/h) | Daaglikse koste (24h @ $1.2/L) |
|---|---|---|
| 100% (Standby) | 480 | $13,824 |
| 75% (Typical) | 380 | $10,944 |
| 50% (Low load) | 280 | $8,064 |
Belangrik: Running a generator below 30% load for extended periods causes “nat stapeling” — unburned fuel accumulates in the exhaust, reducing engine life. Always size your generator so the typical load is between 50-80% van gegradeerde kapasiteit.
Price Breakdown: What Affects the Cost?
The price of a 2000 kW diesel generator ranges from $250,000 aan $450,000 (FOB), depending on several factors:
1. Enjin handelsmerk
The engine is 60-70% of the total cost. Premium brands cost more but offer better reliability and resale value:
- Cummins: Most popular globally, excellent parts availability, 5-10% premie
- Perkins: British engineering, widely used in Europe and Middle East
- PERSOON: German engineering, best for high-performance applications, 15-20% premie
- Weichai / Yuchai: Chinese engine brands, competitive pricing, growing global acceptance
2. Tipe omhulsel
- Oop stel: Lowest cost, requires dedicated generator room
- stille kragopwekker: +15-25% koste, reduces noise to 78 dB(A)
- containerized generator: +25-35% koste, weatherproof, selfoon, quick deployment
3. Alternator Brand
- Stamford / Leroy-Somer: Premium, best for non-linear loads
- Marathon / Mecc Alte: Good quality, competitive pricing
- Chinese brands (Nee, ens.): Budget-friendly, adequate for standard applications
4. Controller
- Deep Sea (DSE): Bedryfstandaard, betroubaar, easy to program
- ComAp: Advanced features, afstandmonitering, multi-unit sync
- SmartGen: Cost-effective Chinese brand, growing market share
How to Choose the Right 2000 kW kragopwekker
Stap 1: Determine Your Power Requirement
List all the equipment you need to power simultaneously. Voeg by 20% headroom for motor starting surges and future expansion. A 2000 kW generator is typically suitable for loads between 1000-1600 kW.
Stap 2: Choose Standby vs. Eerste krag
- Standby: Slegs noodrugsteun, runs less than 200 ure/jaar. The generator can output 100% gegradeerde krag.
- Prime: Deurlopende werking, lopies 8,000+ ure/jaar. De-rate by 10% (output is 90% van nominale krag).
Stap 3: Select the Enclosure
If noise is a concern (residential area, hospitaal, office building), choose a stille kragopwekker. If you need mobility or quick deployment, choose a containerized generator.
Stap 4: Verifieer brandstoftoevoer
A 2000 kW diesel generator at 75% load consumes approximately 380 L/h. For 24-hour operation, you need a base tank of at least 9,120 liters. Plan for daily fuel delivery or install an external day tank.
Installasievereistes
Ventilasie
The generator room must provide adequate airflow for combustion and cooling. A 2000 kW unit requires approximately 12,500 m³/h of ventilation air. Install intake louvers on the low wall and exhaust louvers on the high wall opposite the radiator.
Foundation
The foundation must support the static weight of 25,000 kg plus dynamic loads during operation. A reinforced concrete pad of at least 200mm thickness is recommended, with anti-vibration mounts between the generator and the pad.
Electrical Connection
Use an Outomatiese oordragskakelaar (ATS) to switch between grid and generator power. The ATS should be rated for the full load current and include time-delay features to prevent unnecessary starts during momentary outages.
Onderhoudskedule
Regular maintenance extends engine life and ensures reliable starting when you need it most:
| Interval | Taak |
|---|---|
| Daagliks | Gaan olievlak na, koelmiddel vlak, brandstof vlak, battery spanning |
| Weekliks | Run under load for 30 minute, kyk vir lekkasies |
| Maandeliks | Clean air filter, check belt tension, test safety shutdowns |
| Elke 250 ure | Change oil and oil filter, check valve clearance |
| Elke 500 ure | Replace fuel filter, clean fuel tank, check injector nozzles |
| Elke 1,000 ure | Adjust valve clearance, test alternator insulation, check control system |
| Elke 2,000 ure | Overhaul cylinder head, replace coolant, test alternator winding resistance |
For a detailed checklist, see our diesel generator maintenance schedule guide.
Gereelde Vrae
How much does a 2000 kW diesel generator cost?
A 2000 kW diesel generator costs between $250,000 en $450,000 (FOB), depending on engine brand, tipe omhulsel, and alternator selection. Kontak ons for a detailed quotation based on your specific requirements.
What is the fuel consumption of a 2000 kW kragopwekker?
By 75% laai, a 2000 kW diesel generator consumes approximately 380 L/h. Op volle vrag, consumption rises to 480 L/h.
How long can a 2000 kW generator run continuously?
With proper fuel supply and maintenance, a prime-rated 2000 kW generator can run continuously for 24-48 hours before needing an oil check. For extended operation, schedule brief shutdowns every 500 hours for oil and filter changes.
What size room do I need for a 2000 kW kragopwekker?
The generator dimensions are approximately 7.0×2.4×3.0 meters. Laat ten minste toe 1 meter clearance on all sides for maintenance access, plus space for the radiator airflow and exhaust system.
Kan a 2000 kW generator power a hospital?
Ja, a 2000 kW generator is commonly used for hospital backup power. It must meet NFPA 110 requirements including 10-second start capability. See our hospital generator page for compliance details.
Need a 2000 kW Generator for Your Project?
We are Huaquan Power, a professional generator manufacturer with 15+ jare se ondervinding. Ons 2000 kW diesel Kragopwekkers are built for reliability, doeltreffendheid, and long service life.
- Free technical consultation and generator selection
- Customized solutions with full technical specifications
- Complete delivery, installation and after-sales support
- Global shipping with CE, ISO certifications
Two ways to reach us:
- E-pos: huaquan@huaquanpower.com (we reply within 24 ure)
- WhatsApp: +86 159 0536 0672
Special Offer: Tell us your “power requirement + application scenario”, and we will send you a free Generator Selection Report with recommended models, technical specs, and reference pricing.
Click here to request your free quote →
⚡ Explore Related Solutions
- 🏭 500kW Diesel Generator
- 🏭 1000kW Diesel Generator
- 🏭 500kW YC Diesel Generator
- 🔧 KMS (Cummins/Doosan) Reeks
- 📋 Diesel Generator Sets
- 📋 Order Process — How to Buy
- 📋 Kontak ons
💡 Need a customized solution? Contact our engineering team for project-specific recommendations.