If you are looking for a 50 gerador diesel quilowatts, you need reliable technical data to make the right decision. This guide provides complete specifications, fuel consumption data, pricing, and selection advice for 50 kW generator sets used in industrial, comercial, and standby applications.
Quick Specifications: 50 kW Diesel Generator
| Parâmetro | Especificação |
|---|---|
| Potência nominal | 50 kW |
| Potência nominal (kVA) | 62.5 |
| Tipo de combustível | Diesel |
| Fuel Consumption @ 100% Carregar | 12.5 L/h |
| Fuel Consumption @ 75% Carregar | 9.8 L/h |
| Fuel Consumption @ 50% Carregar | 7.2 L/h |
| Open Set Noise Level | 98 dB(UM) |
| Silent Enclosure Noise | 65 dB(UM) |
| Dimensions (C×L×A, eu) | 2.2×0.9×1.4 |
| Peso (kg) | 1,200 |
| Price Range (FOB) | $8,000 – $15,000 |
Need a precise quote for your specific configuration? contact us for a free customized proposal.
What Applications Use a 50 Gerador de kW?
UM 50 kW diesel generator is a versatile power solution that serves multiple industries and applications:
- Fábricas: Provides backup power for production lines, ensuring zero downtime during grid outages. A single 50 kW unit can support a mid-size factory with critical loads.
- Commercial Buildings: Powers HVAC systems, elevadores, iluminação, and IT infrastructure in office buildings, shopping centers, e hotéis.
- Healthcare Facilities: Serves as emergency backup for hospitals and clinics where power interruption is not an option. Must comply with NFPA 110 requirements for 10-second start. See our hospital generator soluções.
- Centros de dados: Provides Tier III/IV backup power for server rooms and network operations centers. Explore our data center generator options for mission-critical facilities.
- Canteiros de obras: Powers heavy equipment, iluminação, and temporary facilities on remote job sites.
- Mining Operations: Supplies continuous power for extraction equipment, ventilação, and camp facilities in remote mining locations.
Fuel Consumption Details
Understanding fuel consumption is critical for calculating operating costs. O 50 kW diesel generator consumption varies significantly with load:
| Nível de carga | Consumo de combustível (L/h) | Custo Diário (24h @ $1.2/L) |
|---|---|---|
| 100% (Espera) | 12.5 | $360 |
| 75% (Typical) | 9.8 | $282 |
| 50% (Low load) | 7.2 | $207 |
Importante: Running a generator below 30% load for extended periods causes “empilhamento molhado” — unburned fuel accumulates in the exhaust, reducing engine life. Always size your generator so the typical load is between 50-80% de capacidade nominal.
Price Breakdown: What Affects the Cost?
The price of a 50 kW diesel generator ranges from $8,000 para $15,000 (FOB), depending on several factors:
1. Marca do motor
The engine is 60-70% of the total cost. Premium brands cost more but offer better reliability and resale value:
- Cummins: Most popular globally, excellent parts availability, 5-10% prêmio
- Perkins: British engineering, widely used in Europe and Middle East
- PESSOA: German engineering, best for high-performance applications, 15-20% prêmio
- Weichai / Yuchai: Chinese engine brands, competitive pricing, growing global acceptance
2. Tipo de gabinete
- Conjunto aberto: Menor custo, requires dedicated generator room
- gerador silencioso: +15-25% custo, reduces noise to 65 dB(UM)
- containerized generator: +25-35% custo, weatherproof, móvel, quick deployment
3. Alternator Brand
- Stamford / Leroy-Somer: Premium, best for non-linear loads
- Maratona / Mecc Alte: Good quality, competitive pricing
- Chinese brands (Engga, etc.): Budget-friendly, adequate for standard applications
4. Controller
- Mar Profundo (DSE): Padrão da indústria, confiável, easy to program
- ComAp: Advanced features, monitoramento remoto, multi-unit sync
- SmartGen: Cost-effective Chinese brand, growing market share
How to Choose the Right 50 Gerador de kW
Etapa 1: Determine Your Power Requirement
List all the equipment you need to power simultaneously. Adicionar 20% headroom for motor starting surges and future expansion. UM 50 kW generator is typically suitable for loads between 25-40 kW.
Etapa 2: Choose Standby vs. Poder Principal
- Espera: Emergency backup only, runs less than 200 horas/ano. The generator can output 100% potência nominal.
- Melhor: Operação contínua, corre 8,000+ horas/ano. De-rate by 10% (output is 90% de potência nominal).
Etapa 3: Select the Enclosure
If noise is a concern (residential area, hospital, office building), choose a gerador silencioso. If you need mobility or quick deployment, choose a containerized generator.
Etapa 4: Verifique o fornecimento de combustível
UM 50 kW diesel generator at 75% load consumes approximately 9.8 L/h. For 24-hour operation, you need a base tank of at least 235 litros. Plan for daily fuel delivery or install an external day tank.
Requisitos de instalação
Ventilação
The generator room must provide adequate airflow for combustion and cooling. UM 50 kW unit requires approximately 312 m³/h of ventilation air. Install intake louvers on the low wall and exhaust louvers on the high wall opposite the radiator.
Foundation
The foundation must support the static weight of 1,200 kg plus dynamic loads during operation. A reinforced concrete pad of at least 200mm thickness is recommended, with anti-vibration mounts between the generator and the pad.
Electrical Connection
Use an Chave de transferência automática (ATS) to switch between grid and generator power. The ATS should be rated for the full load current and include time-delay features to prevent unnecessary starts during momentary outages.
Cronograma de Manutenção
Regular maintenance extends engine life and ensures reliable starting when you need it most:
| Intervalo | Tarefa |
|---|---|
| Diário | Verifique o nível do óleo, nível do líquido refrigerante, nível de combustível, tensão da bateria |
| Semanalmente | Run under load for 30 minutos, verifique se há vazamentos |
| Mensal | Filtro de ar limpo, check belt tension, test safety shutdowns |
| Todo 250 horas | Change oil and oil filter, check valve clearance |
| Todo 500 horas | Replace fuel filter, clean fuel tank, check injector nozzles |
| Todo 1,000 horas | Adjust valve clearance, test alternator insulation, check control system |
| Todo 2,000 horas | Overhaul cylinder head, replace coolant, test alternator winding resistance |
For a detailed checklist, see our diesel generator maintenance schedule guide.
Perguntas frequentes
How much does a 50 kW diesel generator cost?
UM 50 kW diesel generator costs between $8,000 e $15,000 (FOB), depending on engine brand, tipo de gabinete, and alternator selection. Contate-nos for a detailed quotation based on your specific requirements.
What is the fuel consumption of a 50 gerador de kW?
No 75% carregar, um 50 kW diesel generator consumes approximately 9.8 L/h. Em plena carga, consumption rises to 12.5 L/h.
How long can a 50 kW generator run continuously?
With proper fuel supply and maintenance, a prime-rated 50 kW generator can run continuously for 24-48 hours before needing an oil check. For extended operation, schedule brief shutdowns every 500 hours for oil and filter changes.
What size room do I need for a 50 gerador de kW?
The generator dimensions are approximately 2.2×0.9×1.4 meters. Permitir pelo menos 1 meter clearance on all sides for maintenance access, plus space for the radiator airflow and exhaust system.
Pode um 50 kW generator power a hospital?
Sim, um 50 kW generator is commonly used for hospital backup power. It must meet NFPA 110 requirements including 10-second start capability. See our hospital generator page for compliance details.
Need a 50 kW Generator for Your Project?
We are Poder Huaquan, a professional generator manufacturer with 15+ anos de experiência. Nosso 50 kW diesel Geradores are built for reliability, eficiência, and long service life.
- Free technical consultation and generator selection
- Customized solutions with full technical specifications
- Complete delivery, installation and after-sales support
- Global shipping with CE, ISO certifications
Two ways to reach us:
- E-mail: huaquan@huaquanpower.com (we reply within 24 horas)
- WhatsApp: +86 159 0536 0672
Special Offer: Tell us your “power requirement + application scenario”, and we will send you a free Generator Selection Report with recommended models, technical specs, and reference pricing.
Click here to request your free quote →
⚡ Explore Related Solutions
- 🏭 100kW Diesel Generator
- 🏭 500kW Diesel Generator
- 🏭 1000kW Diesel Generator
- 🏭 500kW YC Diesel Generator
- 🔧 KMS (Cummins/Doosan) Série
- 🏥 Data Center Generator Solutions
- 🏥 Gerador portátil
💡 Need a customized solution? Contact our engineering team for project-specific recommendations.