If you are looking for a 2000 générateur diesel kW, you need reliable technical data to make the right decision. This guide provides complete specifications, fuel consumption data, pricing, and selection advice for 2000 kW generator sets used in industrial, commercial, and standby applications.
Quick Specifications: 2000 kW Diesel Generator
| Paramètre | Spécification |
|---|---|
| Puissance nominale | 2000 kW |
| Puissance nominale (kVA) | 2500 |
| Type de carburant | Diesel |
| Fuel Consumption @ 100% Charger | 480 L/heure |
| Fuel Consumption @ 75% Charger | 380 L/heure |
| Fuel Consumption @ 50% Charger | 280 L/heure |
| Open Set Noise Level | 120 dB(UN) |
| Silent Enclosure Noise | 78 dB(UN) |
| Dimensions (L×L×H, m) | 7.0×2.4×3.0 |
| Poids (kilos) | 25,000 |
| Price Range (FOB) | $250,000 – $450,000 |
Need a precise quote for your specific configuration? contact us for a free customized proposal.
What Applications Use a 2000 Générateur kW?
UN 2000 kW diesel generator is a versatile power solution that serves multiple industries and applications:
- Usines de fabrication: Provides backup power for production lines, ensuring zero downtime during grid outages. A single 2000 kW unit can support a mid-size factory with critical loads.
- Bâtiments commerciaux: Powers HVAC systems, ascenseurs, éclairage, and IT infrastructure in office buildings, shopping centers, and hotels.
- Healthcare Facilities: Serves as emergency backup for hospitals and clinics where power interruption is not an option. Must comply with NFPA 110 requirements for 10-second start. See our hospital generator solutions.
- Centres de données: Provides Tier III/IV backup power for server rooms and network operations centers. Explore our data center generator options for mission-critical facilities.
- Chantiers de construction: Powers heavy equipment, éclairage, and temporary facilities on remote job sites.
- Mining Operations: Supplies continuous power for extraction equipment, ventilation, and camp facilities in remote mining locations.
Fuel Consumption Details
Understanding fuel consumption is critical for calculating operating costs. Le 2000 kW diesel generator consumption varies significantly with load:
| Niveau de charge | Consommation de carburant (L/heure) | Coût quotidien (24h @ $1.2/L) |
|---|---|---|
| 100% (Attendre) | 480 | $13,824 |
| 75% (Typique) | 380 | $10,944 |
| 50% (Low load) | 280 | $8,064 |
Important: Running a generator below 30% load for extended periods causes “empilement humide” — unburned fuel accumulates in the exhaust, reducing engine life. Always size your generator so the typical load is between 50-80% de capacité nominale.
Price Breakdown: What Affects the Cost?
The price of a 2000 kW diesel generator ranges from $250,000 à $450,000 (FOB), depending on several factors:
1. Marque du moteur
The engine is 60-70% of the total cost. Premium brands cost more but offer better reliability and resale value:
- Cummins: Most popular globally, excellent parts availability, 5-10% prime
- Perkins: British engineering, widely used in Europe and Middle East
- PERSONNE: German engineering, best for high-performance applications, 15-20% prime
- Weichai / Yuchai: Chinese engine brands, competitive pricing, growing global acceptance
2. Type de boîtier
- Ensemble ouvert: Lowest cost, requires dedicated generator room
- générateur silencieux: +15-25% coût, reduces noise to 78 dB(UN)
- containerized generator: +25-35% coût, weatherproof, mobile, quick deployment
3. Alternator Brand
- Stamford / Leroy Somer: Premium, best for non-linear loads
- Marathon / Mecc Alte: Good quality, competitive pricing
- Chinese brands (Non, etc.): Budget-friendly, adequate for standard applications
4. Controller
- Mer profonde (DSE): Norme industrielle, fiable, easy to program
- ComAp: Advanced features, surveillance à distance, multi-unit sync
- SmartGen: Cost-effective Chinese brand, growing market share
How to Choose the Right 2000 Générateur kW
Étape 1: Determine Your Power Requirement
List all the equipment you need to power simultaneously. Ajouter 20% headroom for motor starting surges and future expansion. UN 2000 kW generator is typically suitable for loads between 1000-1600 kW.
Étape 2: Choose Standby vs. Puissance principale
- Attendre: Sauvegarde d'urgence uniquement, runs less than 200 heures/an. The generator can output 100% puissance nominale.
- Prime: Fonctionnement continu, court 8,000+ heures/an. De-rate by 10% (output is 90% de puissance nominale).
Étape 3: Select the Enclosure
If noise is a concern (residential area, hôpital, immeuble de bureaux), choose a générateur silencieux. If you need mobility or quick deployment, choose a containerized generator.
Étape 4: Vérifier l'approvisionnement en carburant
UN 2000 kW diesel generator at 75% load consumes approximately 380 L/heure. For 24-hour operation, you need a base tank of at least 9,120 litres. Plan for daily fuel delivery or install an external day tank.
Exigences d'installation
Ventilation
The generator room must provide adequate airflow for combustion and cooling. UN 2000 kW unit requires approximately 12,500 m³/heure of ventilation air. Install intake louvers on the low wall and exhaust louvers on the high wall opposite the radiator.
Foundation
The foundation must support the static weight of 25,000 kilos plus dynamic loads during operation. A reinforced concrete pad of at least 200mm thickness is recommended, with anti-vibration mounts between the generator and the pad.
Electrical Connection
Use an Commutateur de transfert automatique (ATS) to switch between grid and generator power. The ATS should be rated for the full load current and include time-delay features to prevent unnecessary starts during momentary outages.
Calendrier d'entretien
Regular maintenance extends engine life and ensures reliable starting when you need it most:
| Intervalle | Tâche |
|---|---|
| Tous les jours | Vérifier le niveau d'huile, niveau de liquide de refroidissement, niveau de carburant, tension de la batterie |
| Hebdomadaire | Run under load for 30 minutes, vérifier les fuites |
| Mensuel | Clean air filter, check belt tension, test safety shutdowns |
| Chaque 250 heures | Change oil and oil filter, check valve clearance |
| Chaque 500 heures | Replace fuel filter, clean fuel tank, check injector nozzles |
| Chaque 1,000 heures | Adjust valve clearance, test alternator insulation, check control system |
| Chaque 2,000 heures | Overhaul cylinder head, replace coolant, test alternator winding resistance |
For a detailed checklist, see our diesel generator maintenance schedule guide.
Foire aux questions
How much does a 2000 kW diesel generator cost?
UN 2000 kW diesel generator costs between $250,000 et $450,000 (FOB), depending on engine brand, type de boîtier, and alternator selection. Contactez-nous for a detailed quotation based on your specific requirements.
What is the fuel consumption of a 2000 générateur kW?
À 75% charger, un 2000 kW diesel generator consumes approximately 380 L/heure. A pleine charge, consumption rises to 480 L/heure.
How long can a 2000 kW generator run continuously?
With proper fuel supply and maintenance, a prime-rated 2000 kW generator can run continuously for 24-48 hours before needing an oil check. For extended operation, schedule brief shutdowns every 500 hours for oil and filter changes.
What size room do I need for a 2000 générateur kW?
The generator dimensions are approximately 7.0×2.4×3.0 meters. Autoriser au moins 1 meter clearance on all sides for maintenance access, plus space for the radiator airflow and exhaust system.
Un 2000 kW generator power a hospital?
Oui, un 2000 kW generator is commonly used for hospital backup power. It must meet NFPA 110 requirements including 10-second start capability. See our hospital generator page for compliance details.
Need a 2000 kW Generator for Your Project?
We are Puissance Huaquan, a professional generator manufacturer with 15+ années d'expérience. Notre 2000 kW diesel Générateurs are built for reliability, efficacité, and long service life.
- Free technical consultation and generator selection
- Customized solutions with full technical specifications
- Complete delivery, installation and after-sales support
- Global shipping with CE, ISO certifications
Two ways to reach us:
- E-mail: huaquan@huaquanpower.com (we reply within 24 heures)
- WhatsApp: +86 159 0536 0672
Special Offer: Tell us your “power requirement + application scenario”, and we will send you a free Generator Selection Report with recommended models, technical specs, and reference pricing.
Click here to request your free quote →
⚡ Explore Related Solutions
- 🏭 500kW Diesel Generator
- 🏭 1000kW Diesel Generator
- 🏭 500kW YC Diesel Generator
- 🔧 KMS (Cummins/Doosan) Série
- 📋 Diesel Generator Sets
- 📋 Order Process — How to Buy
- 📋 Contactez-nous
💡 Need a customized solution? Contact our engineering team for project-specific recommendations.