I.Core answer

The sound insulation effect of Huaquanfang soundproof generator set (quiet type) is excellent. The operating noise at a distance of 7 meters can be as low as below 75 desibel, significantly lower than the 95-110 decibels of traditional open-frame generator sets.

Comparison itemHuaquan silent type unitTraditional open-rack unit
Noise at 7 meter≤75 decibels85-100 desibel
Noise at 1 meter≤75-85 decibels (depending on power)95-110 desibel
Human perceptionEquivalent to the normal conversation volume of two peopleEquivalent to the sound of a chainsaw or firecrackers
Applicable EnvironmentHospital, kawasan perumahan, pusat data, hoteltapak pembinaan, wilderness areas, and factories far away from crowds

Huaquan Power tips: Huaquan Penjana Senyap sets adopt a fully enclosed noise reduction enclosure filled with multiple layers of sound-absorbing materials, digabungkan dengan reka bentuk muffler yang cekap. Sama ada operasi waktu malam atau penggunaan di kawasan perumahan, ia memastikan operasi yang tenang dan bebas kebimbangan.

II.Perbandingan desibel untuk kesan bisu

Untuk memahami secara intuitif apa 75 desibel ialah, berikut ialah jadual perbandingan bunyi biasa:

Sumber bunyiNilai desibelBerbanding dengan unit senyap Huaquan
perpustakaan lewat malam30dBlebih senyap
Pejabat sunyi40-50dBlebih senyap
Unit senyap Huaquan (di 7 meter)≤75dB
Dua orang itu berbual biasa60-75dBTahap yang sama
unit luar penghawa dingin50-60dBRendah sedikit daripada unit senyap
Jalan yang sibuk70-85dBSetaraf dengan enjin pesawat senyap
Unit bingkai terbuka tradisional (di 7 meter)85-100dB10-25dB lebih tinggi daripada unit senyap
Bunyi gergaji elektrik/bunyi mercun100-110dBTahap unit tradisional

Untuk setiap 10 peningkatan dB, jumlah yang dirasakan oleh telinga manusia lebih kurang dua kali ganda. Unit senyap Huaquan ialah 20-35 dB lebih rendah daripada unit tradisional, yang bermaksud kekerasan yang dirasakan adalah sahaja 1/4 kepada 1/8 daripada unit tradisional.

III. Jaminan Teknikal untuk Kesan Senyap

Set penjana senyap Huaquan mencapai operasi hingar ultra-rendah melalui pelbagai reka bentuk pengurangan hingar:

  1. Struktur pengurangan hingar tidak sepadan impedans berbilang lapisan

Kotak kalis bunyi Huaquan diguna pakai struktur pengurangan hingar galangan halangan berbilang lapisan. Permukaan dalam kotak direka bentuk dengan undulasi cekung dan cembung, yang menjadikan jarak antara enjin pembakaran dalaman dan badan kotak tidak tetap, membentuk beberapa lapisan halangan. Ini menyukarkan bunyi bising untuk membentuk laluan balik biasa.

Ciri-ciri Teknikalpenerangan
reka bentuk strukturPermukaan kotak yang cekung dan cembung mengganggu kembalinya bunyi
Prinsip pengurangan bunyiKetidakpadanan impedans berbilang lapisan untuk mengelakkan pengumpulan gema
penyenyapPenyenyap impedans besar terbina dalam
  1. Kapas penyerap bunyi yang lebih tebal + interlayer lembaran tergalvani

Bahagian dalam kotak kalis bunyi Huaquan diguna pakai struktur penebat bunyi dua lapis:

bahankesan
Kapas kalis bunyi yang lebih tebalBahan penyerap bunyi yang sangat kalis api, mampu menyerap tenaga bunyi
Lembaran tergalvani berlubangSekat laluan penghantaran hingar, mengelakkan kebakaran dan bunyi bising

Bahagian dalam badan kotak diperbuat daripada bahan penyerap bunyi berprestasi tinggi untuk mengurangkan bunyi unit. Struktur dwi ini “kapas yang menyerap bunyi + lembaran tergalvani” boleh melemahkan bunyi dengan 30%-40%.

  1. Kepungan pengurangan hingar tertutup sepenuhnya

Kandang kalis bunyi Huaquan diguna pakai struktur tertutup sepenuhnya dan diperbuat daripada plat keluli, menampilkan pengedap yang baik, rintangan hujan dan salji, dan pencegahan habuk.

Ciri-ciri Prosespenerangan
Bahan kotakPlat keluli tergelek sejuk standard kebangsaan, pemotongan laser, mengimpal, dan salutan serbuk dan cat penaik
rawatan permukaanRawatan teknologi lukisan semburan, tahan kakisan dan bebas karat
reka bentuk strukturReka bentuk modular, mudah untuk memasang dan membuka, dan penampilan yang elegan
fungsi pelindungDwi fungsi pengurangan hingar dan kalis hujan
  1. Penjana bunyi rendah

Kuasa Huaquan bermula dari sumber dan menerima pakai bunyi rendah Penjana dengan ciri senyap terbina dalam, secara asasnya mengurangkan penjanaan bunyi.

IV.Rujukan Bunyi untuk Unit Senyap Tahap Kuasa Berbeza

kuasa unitTahap bunyi (di 7 meter)Senario yang berkenaan
30kWKira-kira 65-70dBkegunaan isi rumah, kedai-kedai kecil, hospital
70kWKira-kira 70-72dBPos dan telekomunikasi, komunikasi, rumah tumpangan, hotel
300kWKira-kira 72-75dBHospital, bangunan tinggi, perusahaan perindustrian dan perlombongan
500kW≤75dBPusat data, kilang besar
600kWKira-kira 75dBProjek perindustrian berskala besar

Huaquan mengingatkan anda bahawa kesan pengurangan hingar stesen janakuasa bersepadu bisu pintar boleh dikawal di bawah 70 desibel, memenuhi piawaian antarabangsa.

V. Senario Berkenaan Unit Senyap

Set penjana senyap Huaquan digunakan secara meluas di tempat yang mempunyai keperluan bunyi yang ketat:

medan permohonansenario tipikalKeperluan bunyi
hospitalBilik bedah, ICU, bekalan kuasa siap sedia kecemasanWaktu malam ≤ 55dB, Waktu siang ≤ 65dB
komuniti kediamanBekalan kuasa siap sedia kecemasanPada waktu malam, ia adalah ≤50-55dB
Hotel/rumah tumpanganBekalan kuasa siap sedia, bekalan kuasa dewan perjamuanTahap hingar siang hari ≤60dB
pusat data24-bekalan kuasa tidak terganggu jamTerdapat keperluan tertentu mengenai bunyi bising
Stesen pangkalan komunikasiBekalan kuasa siap sedia untuk stesen pangkalan jauhOperasi tanpa pemandu, dengan kelebihan jelas bunyi yang rendah
bangunan tinggiLif, perlindungan kebakaran, bekalan kuasa kecemasanIa adalah perlu untuk memenuhi keperluan perlindungan alam sekitar
perusahaan perindustrian dan perlombonganBekalan kuasa siap sedia di kawasan kilangBunyi yang rendah diperlukan di kawasan perumahan

The main difference between silent units and regular generator sets lies in the addition of sound elimination devices, primarily intended for households and places with stringent noise control requirements.

VI.Comprehensive Comparison between Silent Air Conditioning Units and Open-Rack Air Conditioning Units

comparative dimensionHuaquan silent type unitHuaquan open-frame unit
Noise at 7 meter≤75dB85-100dB
Human perceptionNormal conversational volumeBunyi gergaji elektrik/bunyi mercun
fungsi pelindungRainproof, snowproof, dustproofA computer room needs to be built for protection
Appearance designElegant appearance, customizable color optionsIndustrial appearance
Installation requirementsIt can be placed directly outdoors, without the need for a machine roomA machine room or a rain shelter needs to be built
priceRelatively high (+20%-30%)lower
Senario yang berkenaanResidential areas, hospital, hotel, pusat datatapak pembinaan, wilderness, factories far away from crowds

VII. Common Issues

S1: How quiet is 75 desibel?

A: 75 decibels is approximately equivalent to the volume of normal face-to-face communication between two people. This means:

  • It will not affect normal conversation from a distance of 7 meter
  • Using it at night will not disturb residentsrest
  • The hospital environment is safe for use

S2: Can the silent air conditioning unit be used outdoors in rainy weather?

A: ya, ia boleh. The Huaquan soundproof box is made of steel plates, with a rust-proof paint coating on the surface. It features noise reduction and waterproof capabilities. The box is fully enclosed, with good sealing, providing protection against rain, salji, and dust.

S3: Does a silent air conditioning unit require an additional machine room?

A: No need. Huaquan’s silent unit adopts a fully enclosed noise reduction enclosure with high protection level, which can be directly placed on a flat outdoor ground without the need to build a machine room, greatly saving installation costs and time.

Q4: Are the noises produced by silent air conditioning units of different power levels the same?

A: There are slight differences. Secara umumnya, higher power tends to result in slightly louder noise

  • 30-100kW:65-72dB
  • 100-300kW:70-75dB
  • 300-600kW:72-78dB

Namun begitu, all Huaquan silent units are controlled to be around 75dB (at a distance of 7 meter), which is much lower than traditional units.

Q5: Will the noise reduction effect of the silent unit degrade over time?

A: With proper use and maintenance, the sound insulation effect will not significantly deteriorate. The Huaquan sound insulation box body is made of high-flame-retardant sound insulation cotton and galvanized sheet metal partitions, ensuring good durability. It is recommended to regularly check the status of the box body’s sealing strips and sound absorption materials, and replace them promptly if damaged.

Q6: Can silent air conditioning units be used in data centers?

A: ya, the Huaquan 500kW silent unit has been widely used in data centers. Equipped with a self-starting control system, it achieves unattended operation and ensures 24-hour uninterrupted power supply. The noise level at a distance of 7 meters is ≤75dB, meeting the requirements of data centers for the operating environment.

📌 Summary: Huaquan Silent Generator SetQuiet, Boleh dipercayai, and Widely Applicable

The sound insulation effect of Huaquanfang’s loudspeaker generator set is at the leading level in the industry. The core technical parameters are as follows:

parameterHuaquan Standard
Noise at 7 meter≤75 decibels (equivalent to normal conversation volume)
Noise reduction technologyStruktur pengurangan hingar tidak sepadan impedans berbilang lapisan + ultra-thick sound-absorbing cotton + perforated galvanized sheet
Bahan kotakPlat keluli tergelek sejuk standard kebangsaan, with corrosion resistance achieved through spraying treatment
fungsi pelindungIntegrated noise reduction, rainproof, and dustproof
Senario yang berkenaanHospital, residences, pusat data, hotel, stesen pangkalan komunikasi

Core advantages of Huaquan Power’s silent unit:

  1. Ultra-quiet operation: noise level at 7 meters is ≤75dB, significantly lower than the 95-110dB of traditional units
  2. Multiple noise reduction technology: multi-layer impedance mismatch noise elimination structure + built-in large muffler
  3. Fully enclosed box: rainproof, snowproof, dustproof, suitable for direct outdoor use
  4. Intelligent control: Configurable self-starting control system for unattended operation
  5. Widely used: ideal choice for noise-sensitive places such as hospitals, pusat data, kawasan perumahan, and hotels

For users who need to use generator sets in residential areas, hospital, hotel, pusat data, and other places with strict noise requirements, Huaquan’s silent generator sets are an ideal choice for their high efficiency, kebolehpercayaan, and quietness.

For more technical details on silent unit technology or to obtain selection advice, please contact Huaquan Power’s customer service