I.Core answer
The sound insulation effect of Huaquanfang soundproof generator set (quiet type) is excellent. The operating noise at a distance of 7 meters can be as low as below 75 desibel, significantly lower than the 95-110 decibels of traditional open-frame generator sets.
| Comparison item | Huaquan silent type unit | Traditional open-rack unit |
| Noise at 7 meter | ≤75 decibels | 85-100 desibel |
| Noise at 1 meter | ≤75-85 decibels (depending on power) | 95-110 desibel |
| Human perception | Equivalent to the normal conversation volume of two people | Equivalent to the sound of a chainsaw or firecrackers |
| Applicable Environment | Hospital, kawasan perumahan, pusat data, hotel | tapak pembinaan, wilderness areas, and factories far away from crowds |
Huaquan Power tips: Huaquan Penjana Senyap sets adopt a fully enclosed noise reduction enclosure filled with multiple layers of sound-absorbing materials, digabungkan dengan reka bentuk muffler yang cekap. Sama ada operasi waktu malam atau penggunaan di kawasan perumahan, ia memastikan operasi yang tenang dan bebas kebimbangan.
II.Perbandingan desibel untuk kesan bisu
Untuk memahami secara intuitif apa 75 desibel ialah, berikut ialah jadual perbandingan bunyi biasa:
| Sumber bunyi | Nilai desibel | Berbanding dengan unit senyap Huaquan |
| perpustakaan lewat malam | 30dB | lebih senyap |
| Pejabat sunyi | 40-50dB | lebih senyap |
| Unit senyap Huaquan (di 7 meter) | ≤75dB | — |
| Dua orang itu berbual biasa | 60-75dB | Tahap yang sama |
| unit luar penghawa dingin | 50-60dB | Rendah sedikit daripada unit senyap |
| Jalan yang sibuk | 70-85dB | Setaraf dengan enjin pesawat senyap |
| Unit bingkai terbuka tradisional (di 7 meter) | 85-100dB | 10-25dB lebih tinggi daripada unit senyap |
| Bunyi gergaji elektrik/bunyi mercun | 100-110dB | Tahap unit tradisional |
Untuk setiap 10 peningkatan dB, jumlah yang dirasakan oleh telinga manusia lebih kurang dua kali ganda. Unit senyap Huaquan ialah 20-35 dB lebih rendah daripada unit tradisional, yang bermaksud kekerasan yang dirasakan adalah sahaja 1/4 kepada 1/8 daripada unit tradisional.
III. Jaminan Teknikal untuk Kesan Senyap
Set penjana senyap Huaquan mencapai operasi hingar ultra-rendah melalui pelbagai reka bentuk pengurangan hingar:
- Struktur pengurangan hingar tidak sepadan impedans berbilang lapisan
Kotak kalis bunyi Huaquan diguna pakai struktur pengurangan hingar galangan halangan berbilang lapisan. Permukaan dalam kotak direka bentuk dengan undulasi cekung dan cembung, yang menjadikan jarak antara enjin pembakaran dalaman dan badan kotak tidak tetap, membentuk beberapa lapisan halangan. Ini menyukarkan bunyi bising untuk membentuk laluan balik biasa.
| Ciri-ciri Teknikal | penerangan |
| reka bentuk struktur | Permukaan kotak yang cekung dan cembung mengganggu kembalinya bunyi |
| Prinsip pengurangan bunyi | Ketidakpadanan impedans berbilang lapisan untuk mengelakkan pengumpulan gema |
| penyenyap | Penyenyap impedans besar terbina dalam |
- Kapas penyerap bunyi yang lebih tebal + interlayer lembaran tergalvani
Bahagian dalam kotak kalis bunyi Huaquan diguna pakai struktur penebat bunyi dua lapis:
| bahan | kesan |
| Kapas kalis bunyi yang lebih tebal | Bahan penyerap bunyi yang sangat kalis api, mampu menyerap tenaga bunyi |
| Lembaran tergalvani berlubang | Sekat laluan penghantaran hingar, mengelakkan kebakaran dan bunyi bising |
Bahagian dalam badan kotak diperbuat daripada bahan penyerap bunyi berprestasi tinggi untuk mengurangkan bunyi unit. Struktur dwi ini “kapas yang menyerap bunyi + lembaran tergalvani” boleh melemahkan bunyi dengan 30%-40%.
- Kepungan pengurangan hingar tertutup sepenuhnya
Kandang kalis bunyi Huaquan diguna pakai struktur tertutup sepenuhnya dan diperbuat daripada plat keluli, menampilkan pengedap yang baik, rintangan hujan dan salji, dan pencegahan habuk.
| Ciri-ciri Proses | penerangan |
| Bahan kotak | Plat keluli tergelek sejuk standard kebangsaan, pemotongan laser, mengimpal, dan salutan serbuk dan cat penaik |
| rawatan permukaan | Rawatan teknologi lukisan semburan, tahan kakisan dan bebas karat |
| reka bentuk struktur | Reka bentuk modular, mudah untuk memasang dan membuka, dan penampilan yang elegan |
| fungsi pelindung | Dwi fungsi pengurangan hingar dan kalis hujan |
- Penjana bunyi rendah
Kuasa Huaquan bermula dari sumber dan menerima pakai bunyi rendah Penjana dengan ciri senyap terbina dalam, secara asasnya mengurangkan penjanaan bunyi.
IV.Rujukan Bunyi untuk Unit Senyap Tahap Kuasa Berbeza
| kuasa unit | Tahap bunyi (di 7 meter) | Senario yang berkenaan |
| 30kW | Kira-kira 65-70dB | kegunaan isi rumah, kedai-kedai kecil, hospital |
| 70kW | Kira-kira 70-72dB | Pos dan telekomunikasi, komunikasi, rumah tumpangan, hotel |
| 300kW | Kira-kira 72-75dB | Hospital, bangunan tinggi, perusahaan perindustrian dan perlombongan |
| 500kW | ≤75dB | Pusat data, kilang besar |
| 600kW | Kira-kira 75dB | Projek perindustrian berskala besar |
Huaquan mengingatkan anda bahawa kesan pengurangan hingar stesen janakuasa bersepadu bisu pintar boleh dikawal di bawah 70 desibel, memenuhi piawaian antarabangsa.
V. Senario Berkenaan Unit Senyap
Set penjana senyap Huaquan digunakan secara meluas di tempat yang mempunyai keperluan bunyi yang ketat:
| medan permohonan | senario tipikal | Keperluan bunyi |
| hospital | Bilik bedah, ICU, bekalan kuasa siap sedia kecemasan | Waktu malam ≤ 55dB, Waktu siang ≤ 65dB |
| komuniti kediaman | Bekalan kuasa siap sedia kecemasan | Pada waktu malam, ia adalah ≤50-55dB |
| Hotel/rumah tumpangan | Bekalan kuasa siap sedia, bekalan kuasa dewan perjamuan | Tahap hingar siang hari ≤60dB |
| pusat data | 24-bekalan kuasa tidak terganggu jam | Terdapat keperluan tertentu mengenai bunyi bising |
| Stesen pangkalan komunikasi | Bekalan kuasa siap sedia untuk stesen pangkalan jauh | Operasi tanpa pemandu, dengan kelebihan jelas bunyi yang rendah |
| bangunan tinggi | Lif, perlindungan kebakaran, bekalan kuasa kecemasan | Ia adalah perlu untuk memenuhi keperluan perlindungan alam sekitar |
| perusahaan perindustrian dan perlombongan | Bekalan kuasa siap sedia di kawasan kilang | Bunyi yang rendah diperlukan di kawasan perumahan |
The main difference between silent units and regular generator sets lies in the addition of sound elimination devices, primarily intended for households and places with stringent noise control requirements.
VI.Comprehensive Comparison between Silent Air Conditioning Units and Open-Rack Air Conditioning Units
| comparative dimension | Huaquan silent type unit | Huaquan open-frame unit |
| Noise at 7 meter | ≤75dB | 85-100dB |
| Human perception | Normal conversational volume | Bunyi gergaji elektrik/bunyi mercun |
| fungsi pelindung | Rainproof, snowproof, dustproof | A computer room needs to be built for protection |
| Appearance design | Elegant appearance, customizable color options | Industrial appearance |
| Installation requirements | It can be placed directly outdoors, without the need for a machine room | A machine room or a rain shelter needs to be built |
| price | Relatively high (+20%-30%) | lower |
| Senario yang berkenaan | Residential areas, hospital, hotel, pusat data | tapak pembinaan, wilderness, factories far away from crowds |
VII. Common Issues
S1: How quiet is 75 desibel?
A: 75 decibels is approximately equivalent to the volume of normal face-to-face communication between two people. This means:
- It will not affect normal conversation from a distance of 7 meter
- Using it at night will not disturb residents’ rest
- The hospital environment is safe for use
S2: Can the silent air conditioning unit be used outdoors in rainy weather?
A: ya, ia boleh. The Huaquan soundproof box is made of steel plates, with a rust-proof paint coating on the surface. It features noise reduction and waterproof capabilities. The box is fully enclosed, with good sealing, providing protection against rain, salji, and dust.
S3: Does a silent air conditioning unit require an additional machine room?
A: No need. Huaquan’s silent unit adopts a fully enclosed noise reduction enclosure with high protection level, which can be directly placed on a flat outdoor ground without the need to build a machine room, greatly saving installation costs and time.
Q4: Are the noises produced by silent air conditioning units of different power levels the same?
A: There are slight differences. Secara umumnya, higher power tends to result in slightly louder noise
- 30-100kW:65-72dB
- 100-300kW:70-75dB
- 300-600kW:72-78dB
Namun begitu, all Huaquan silent units are controlled to be around 75dB (at a distance of 7 meter), which is much lower than traditional units.
Q5: Will the noise reduction effect of the silent unit degrade over time?
A: With proper use and maintenance, the sound insulation effect will not significantly deteriorate. The Huaquan sound insulation box body is made of high-flame-retardant sound insulation cotton and galvanized sheet metal partitions, ensuring good durability. It is recommended to regularly check the status of the box body’s sealing strips and sound absorption materials, and replace them promptly if damaged.
Q6: Can silent air conditioning units be used in data centers?
A: ya, the Huaquan 500kW silent unit has been widely used in data centers. Equipped with a self-starting control system, it achieves unattended operation and ensures 24-hour uninterrupted power supply. The noise level at a distance of 7 meters is ≤75dB, meeting the requirements of data centers for the operating environment.
📌 Summary: Huaquan Silent Generator Set – Quiet, Boleh dipercayai, and Widely Applicable
The sound insulation effect of Huaquanfang’s loudspeaker generator set is at the leading level in the industry. The core technical parameters are as follows:
| parameter | Huaquan Standard |
| Noise at 7 meter | ≤75 decibels (equivalent to normal conversation volume) |
| Noise reduction technology | Struktur pengurangan hingar tidak sepadan impedans berbilang lapisan + ultra-thick sound-absorbing cotton + perforated galvanized sheet |
| Bahan kotak | Plat keluli tergelek sejuk standard kebangsaan, with corrosion resistance achieved through spraying treatment |
| fungsi pelindung | Integrated noise reduction, rainproof, and dustproof |
| Senario yang berkenaan | Hospital, residences, pusat data, hotel, stesen pangkalan komunikasi |
Core advantages of Huaquan Power’s silent unit:
- Ultra-quiet operation: noise level at 7 meters is ≤75dB, significantly lower than the 95-110dB of traditional units
- Multiple noise reduction technology: multi-layer impedance mismatch noise elimination structure + built-in large muffler
- Fully enclosed box: rainproof, snowproof, dustproof, suitable for direct outdoor use
- Intelligent control: Configurable self-starting control system for unattended operation
- Widely used: ideal choice for noise-sensitive places such as hospitals, pusat data, kawasan perumahan, and hotels
For users who need to use generator sets in residential areas, hospital, hotel, pusat data, and other places with strict noise requirements, Huaquan’s silent generator sets are an ideal choice for their high efficiency, kebolehpercayaan, and quietness.
For more technical details on silent unit technology or to obtain selection advice, please contact Huaquan Power’s customer service