< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=818233107660385&ev=PageView&noscript=1" />
x
Йодышдам таче колто
Писын цитате

What is the voltage of Huaquan high-voltage generator set?

I.Тӱҥ вашмут

The voltage range of Huaquan’s high-voltage generator sets spans from 3,300V (3.3kV) to 13,800V (13.8kV), encompassing the mainstream voltage levels in the medium and high-voltage power generation sector. Notably, 10.5kV (10,500V) stands as the primary voltage level for Huaquan’s high-voltage units, finding widespread application in scenarios such as data centers, medical centers, large mines, and oil fields.

voltage levelCommon applicationsTypical power matching
3.3kVSmall and medium-sized industrial projects500-1000кВт
6.0kVMine and oilfield parallel operation system1000-2000кВт
10.5kV (main power)Данный рӱдер-влак, medical centers, large mines1000-3000кВт
13.8kVLarge-scale power stations, overseas general contracting2000kW+

Huaquan Power ушештара: Huaquan provides customized solutions for a full range of high-voltage generator sets from 3kV to 13.8kV. Specific voltage levels can be customized according to project requirements, with a power range of 500kVA to 5200kVA.

II.Detailed explanation of various voltage levels

  1. 10.5kV (10500V) – the primary voltage level

10.5kV is the most commonly used voltage level for Huaquan’s high-voltage units and also a common distribution voltage in high-voltage power grids.

parameterHuaquan 1000kW unitHuaquan 1200kW unit
rated voltage10.5kV10.5kV
rated current61.9ИК82.5ИК
лектыш куат1000кВт1200кВт
Applicable scenariosMedical center, данный рӱдерLarge mines, данный рӱдер-влак

Advantages of high voltage and low current:

  • Under a voltage of 10.5kV, the current of a 1000kW unit is only 61.9A, and the current of a 1200kW unit is only 82.5A
  • Typical high voltage and low current characteristics, centralized power supply, high voltage regulation accuracy, and strong harmonic suppression capability
  • It is particularly suitable for long-distance power transmission сценарий-влак

Typical application case:

  • A data center in Jinan: Purchased multiple Huaquan high-voltage generator sets to provide continuous and stable power supply for the data center
  • Solar-thermal complementary power generation project in Nyima County, Сизан: successfully operated at an altitude of 5600 meters and in harsh environment at -40℃
  1. 6.0kV (6000V) – commonly used in mine parallel operation systems

6.0kV is a commonly used voltage level in large industrial projects such as mines and oil fields, especially suitable for multi-machine parallel configurations.

projectA mining company in Heilongjiang
total power2400кВт (2 units of 1200kW operating in parallel)
voltage level6000V
engine configurationV-type 12-cylinder, electronically controlled high-pressure common rail, National III emission standard
Единице конфигураций2 турбокомпрессор-влак, 2 intake air filters, 2 starter motors
intelligent systemHuaquan Cloud Intelligent Monitoring System

Advantages of high-voltage parallel operation:

  • Two 1200kW units connected in parallel form a 2400kW high-voltage power station
  • Stable power supply, strong harmonic suppression capability, and high voltage regulation accuracy
  • Suitable for high energy consumption scenarios such as large-scale mining and oil fields
  1. 13.8kV and other voltage levels

The voltage range of Huaquan high-voltage generator sets covers 3kV to 13.8kV, meeting the grid standards of different countries and regions:

voltage levelApplicable regions/standardstypical scenario
3.3kVInternational StandardSmall and medium-sized industrial projects
6.0kVDomestic mine/oilfield standardsLarge mining parallel operation system
10.5kVMain domestic distribution voltageДанный-влак рӱдер, medical center
13.8kVNorth American standard/export projectOverseas general contracting, large-scale power stations

III. Comparison between high-voltage and low-voltage generator sets

таҥастарымаш габаритHuaquan high-voltage generator setHuaquan conventional low-voltage unit
voltage level3kV~13.8kV400V/230V
current magnitudeИзи (1000kW→61.9A)Large (1000kW→1800A)
transmission distanceFar (several tens of kilometers)Nearby (a few hundred meters)
Line lossminimalLarge (significant I²R loss)
Power supply concentrationКукшо (Capable of centralized power supply)Лапка (requires more distribution points)
harmonic suppressionstronggeneral
Pressure regulation accuracyКукшо (±0.5%)Чумыр налмаште (±1%)
Applicable scenariosLong-distance power transmission, large centralized loadLocal power distribution, small and medium-sized loads
Typical ApplicationsДанный-влак рӱдер, mine, oil field, airportЗавод-влак, илыме вер-влак, чоҥымо площадкы-влак

Huaquan’s Advantages: Huaquan’s high-voltage units adopt a design featuring high voltage and low current, resulting in minimal power loss during power transmission, making them particularly suitable for long-distance power transmission.

IV.Core Technical Parameters of Huaquan High-Pressure Unit

parameterHuaquan Standard
voltage range3kV~13.8kV
куатан диапазон500kVA~5200kVA
voltage accuracy±0.5%
structural formDual bearings or single bearing (муышы)
Coil/bearing monitoringPT100 standard
bearing lifeӰмбалне 100,000 шагат паша

Typical configuration case (Huaquan 1000kW containerized high-voltage unit):

configuration itemspecification
Overall dimensions7.5m × 2.5m × 2.9m
engineWeichai V-type 12-cylinder engine, with a standby power of 1210kW and a displacement of 32.9L
Technical FeaturesElectronic fuel injection high-pressure common rail, dual air filters, dual turbocharging
генераторInge motor, voltage 10.5kV, current 61.9A
Control methodSelf-starting control cabinet, automatic switching in case of mains power failure

V.Applicable Scenarios of High-Voltage Generator Sets

  1. Данный-влак рӱдер
йодешHuaquan solution
Power supply reliabilityHuaquan high-voltage units have been applied in multiple projects, including the Jinan Data Center
Напряженийын пеҥгыдылыкшеHigh voltage and low current, high voltage regulation accuracy, strong harmonic suppression capability
remote power supplyThe advantage is obvious when the distance between the data center and the generator set is relatively large
  1. Mines and oil fields
йодешHuaquan solution
High-power power supplySingle machine 1200kW, parallel operation up to 2400kW+
Long-distance power transmissionWith an output of 6000V or 10500V, there is minimal transmission loss over distances of tens of kilometers
Adaptation to harsh environmentsThe high-voltage unit for mines has been successfully applied in Heilongjiang Mining Company
  1. Medical centers, airports
йодешHuaquan solution
аварийный электропитаниеHigh-voltage unit self-starts, with a response time of seconds in case of mains power interruption
high reliabilityHuaquan high-voltage units have been applied in industries such as medical centers and airport power supply
Centralized power supplyOne high-voltage unit can cover the entire hospital/terminal building
  1. Plateaus and extreme environments
пӱртӱс йырвелHuaquan performance
5600 meters above sea levelThe solar-thermal complementary power generation project in Nyima County, Сизан, has been successfully operational
-40℃ low temperatureRich operational experience in high-altitude and harsh environments at -40℃
special working conditionsIt has numerous operational cases in harsh environments such as industrial continuous power supply, high altitude, and ultra-low temperature

VI.Common Issues

Q1: Why is the voltage of a high-voltage generator set 10.5 kV instead of 10 kV?

ИК: The rated voltage of a generator is usually 5% higher than the rated voltage of the power grid to compensate for voltage drops on the transmission lines. When the rated voltage of the power grid is 10kV, the rated voltage of the generator is designed to be 10.5kV. When the 10.5kV output reaches the user end through the transmission lines, the voltage drops to around 10kV, ensuring normal operation of the equipment.

Q2: Which is more suitable for me, a high-voltage generator set or a low-voltage one?

ИК: Huaquan Power recommends referring to the following standards:

Your requestТемлыме йӧнreason
Single unit power < 500 кВтLow-voltage unit (400V)Low-voltage equipment is mature and low-cost
The distance between the load and the generator is less than 500 метрLow-voltage unit (400V)Line loss is acceptable
Single unit power > 1000 кВтHigh-voltage unit (10.5kV)High voltage and low current, with a more reasonable equipment capacity
The distance between the load and the generator is greater than 1000 метрHigh-voltage unit (10.5kV)The loss of power transmission over long distances is small
Data center/Medical centerHigh-voltage unit (10.5kV)Centralized power supply, high voltage regulation accuracy
Multiple high-power units operating in parallelHigh-voltage unit (6kV/10.5kV)The parallel operation system is mature and has strong harmonic suppression capability

Q3: What are the protection level and insulation level of Huaquan high-voltage generator sets?

ИК: Huaquan’s high-voltage Генератор-влак have a protection level up to IP23 (rain-proof) and an insulation level of H. The containerized units have a higher protection level and can be used outdoors in all weather conditions.

Q4: What is the service life of a high-voltage generator set?

ИК: The design lifespan of Huaquan high-voltage generator sets is over 20 курым, with the generator bearings having a lifespan of over 100,000 шагат паша. The engine, when maintained according to specifications, can undergo a major overhaul after 30,000 шагат паша.

Q5: What are some successful cases of Huaquan high-voltage generator sets?

ИК: Huaquan high-pressure units have been successfully applied in the following typical projects:

  • China Mobile Data Center: High-voltage parallel power supply
  • Jiangsu Nuclear Power Station: Emergency Standby Power Supply
  • Solar-thermal complementary power generation project in Nyima County, Сизан: at an altitude of 5600 meters and in a -40℃ plateau environment
  • A mining company in Heilongjiang: 2400кВт (2×1200kW) high-voltage parallel operation system
  • A data center in Jinan: multiple high-voltage units provide centralized power supply

📌 Иктешлымаш: Quick Reference for Voltage Parameters of Huaquan High-Voltage Generator Sets

voltage levelTypical powerTypical currentApplicable scenarios
3.3kV500-1000кВт87-175ИКSmall and medium-sized industrial projects
6.0kV1000-2000кВт (параллельный операций)96-192ИКMine and oil field parallel operation system
10.5kV (main power)1000-3000кВт55-165ИКДанный рӱдер-влак, medical centers, large mines
13.8kV2000kW+83А+Large-scale power stations, overseas projects

Core advantages of Huaquan Power’s high-pressure units:

  1. Wide voltage range: full series from 3kV to 13.8kV, with power coverage from 500kVA to 5200kVA
  2. High voltage and low current: low transmission loss, suitable for long-distance power supply
  3. High voltage regulation accuracy: voltage accuracy ±0.5%, strong harmonic suppression capability
  4. Intelligent control: Huaquan cloud intelligent monitoring system, automatic switching between mains power and резерв куат
  5. Strong environmental adaptability: verified in harsh environments at an altitude of 5600 meters and temperatures of -40℃
  6. Rich application cases: numerous successful cases in data centers, атомный электростанций-влак, mines, нефть рудник-влак, solar thermal power stations, да молат

For more technical details on high-voltage generator sets or to obtain a selection plan, пожалуйста, Huaquan Power-ын клиент-влакым обслуживатлыме службыж дене кылдалтса