What is the decibel level of a silent generator?

What is the noise level in decibels of Huaquan’s Máy phát điện im lặng bộ?

When operating at full capacity, the Huaquan silent generator set can produce noise levels as low as below 75 decibel (measured at a distance of 1 meter from the unit), significantly lower than the 90-110 decibels produced by traditional open-type generator sets.

The comparison of noise data at different measurement distances is as follows:

measurement positionNoise level of Huaquan silent unitMeasurement standard description
Tại 1 meter75dB(MỘT)The factory testing standard is equivalent to the volume of normal conversation between two people
Tại 7 mét65-75dB(MỘT)Simulate actual usage scenarios to meet urban environmental protection requirements
Ordinary open-type unit (Tại 1 meter)95-110dB(MỘT)Equivalent to the sound of an electric saw or firecrackers

Taking Huaquan Power’s 120kW silent generator set as an example, its noise limit at 1 meter is 75dB(MỘT); trong khi Huaquan Power’s 15kW low-power silent generator set can control noise within 60-65 decibel, making it more suitable for quiet environments such as homes.

  1. What does 75 decibels mean? What noise level does it belong to?

75 decibels is roughly equivalent to the volume of two people having a normal conversation face-to-face, which meets the requirements of noise-sensitive places such as hospitals, khu dân cư, trường học, và trung tâm dữ liệu.

Daily Noise Comparison Reference Table:

noise sourceDecibel valueHuman perception
Late-night library30dBVery quiet
Normal conversation60-75dBcomfortable
Huaquan silent generator (Tại 7 mét)65-75dBAcceptable, does not affect conversation
Ordinary Máy phát điện Diesel (Tại 1 meter)95-110dBIt sounds like an electric saw, unbearable
aircraft engine110dB+Eardrum discomfort

What does the noise level of Huaquan Power‘s silent generator set signify? It ensures quiet and worry-free operation, whether it’s for emergency surgery in the middle of the night, life monitoring in the ICU, or power supply in residential areas at night.

III. Are the noise levels the same for different power models?

The noise levels of Huaquan silent generator sets with different power levels vary slightly, but they are all controlled below 75 decibel. Nói chung, the lower the power, the lower the noise.

Unit model/powernoise valuemeasure distanceApplicable scenarios
HQ15GF (15kW small model)60-65dB(MỘT)Tại 1 meterHousehold use, small shop
HQ120GF (120kW medium-sized)75dB(MỘT)Tại 1 meterBệnh viện, tòa nhà văn phòng
HQ500GF (500kW large-scale)75dB(MỘT)Tại 1 meterTrung tâm dữ liệu, factory
Conventional models across various power ranges65-75dB(MỘT)Tại 7 métGeneral for cities and residential areas

Ghi chú: The entire series of Huaquan Power’s silent units are designed with a unified noise reduction standard, targeting a noise level of 75dB(MỘT) regardless of power output, ensuring a consistent user experience.

  1. How does Huaquan silent generator achieve low noise?

Answer: Huaquan Power controls the noise of the generator set below 75 decibels through five major silent black technologies:

  1. Fully enclosed noise-reducing enclosure

The Huaquan soundproof enclosure is treated with spray painting technology, making it corrosion-resistant and rust-free. The enclosure is made of thickened cold-rolled steel plates that are cut and bent into a solid structure with an attractive appearance.

  1. Multi-layer sound-absorbing material

The inner wall of the box is filled with 6cm thick sound-absorbing cotton, combined with perforated galvanized soundproof boards, forming a dual noise reduction structure of “bông hút âm + galvanized boards”, which can reduce noise by 30%-40%.

  1. Maze-style air intake and exhaust sound-absorbing channel

The air intake and exhaust channels are designed with a three-layer blocking labyrinth structure: this ensures the sufficient input of fresh air, effectively cools the unit during operation, and also effectively seals the noise transmission path, achievingventilation without sound transmission”.

  1. High-efficiency filter-type smoke exhaust silencer

The exhaust system is equipped with an industrial-grade resistive muffler, which eliminates the high-frequencyhissingsound produced when high-temperature and high-pressure exhaust gas is ejected, further reducing exhaust noise.

  1. Shock absorption design

A rubber automotive shock absorber is installed between the engine and the base, featuring a dual-screw design, effectively reducing vibration transmission and preventing the box from becoming alarge speaker”.

  1. What are the applicable scenarios for Huaquan silent Máy phát điện?

Huaquan silent generator sets, with their ultra-low noise characteristics, have become thestandard equipmentin the following scenarios:

Kịch bản ứng dụngWhy choose Huaquan silent unitRecommended power range
Hospital/Operating RoomEmergency surgeries in the middle of the night and ICU monitoring require absolute silence, and the ordinary unit with a noise level of 110dB cannot be used100-500kW
Residential area/housePower supply at night does not disturb residents and complies with community noise management regulations10-100kW
School/libraryThe teaching environment is sensitive to noise and requires silence50-200kW
trung tâm dữ liệu24-hour uninterrupted power supply requires a low-noise operating environment300-1000kW+
Night construction/emergency rescueThere are noise restrictions for urban nighttime operations, and silent units are a compliant choice50-300kW
Hotel/shopping mallThe business premises need to maintain a comfortable environment100-500kW
Large-scale event/concertEnsure power supply without affecting the performance effect200-1000kW+

Typical reference: Huaquan Power’s 500kW silent generator set has been widely used in hospitals, trung tâm dữ liệu, và các kịch bản khác, with users reportingit really works well”.

  1. Noise Comparison between Silent and Ordinary Generator Sets

The noise control advantage of Huaquan silent generator sets is very obvious. The following is a detailed comparison:

Comparison itemHuaquan silent generator setOrdinary open-type unit
Noise at 1 meter75dB(MỘT)95-110dB(MỘT)
Noise at 7 mét65-75dB(MỘT)85-100dB(MỘT)
Human perceptionNormal conversation volumeSimilar to the sound of a chainsaw or firecrackers
Applicable EnvironmentCities, khu dân cư, bệnh viện, trường họcConstruction sites, wilderness, factories far away from crowds
protective performanceIP23 is rainproof and dustproof, suitable for outdoor placementA computer room needs to be built for protection
priceRelatively high (+20%-30%)lower

Key conclusion: The noise of a regular unit is equivalent to the sound of an airplane engine at 110 decibel, whereas the Huaquan silent unit can control the noise to below 75 decibel, which is equivalent to a noise reduction of over 35 decibel. For every 10 decibels increase, the perceived volume by the human ear approximately doublesthis means that the actual auditory loudness of the Huaquan silent unit is only 1/8 ĐẾN 1/4 of that of the regular unit.

VII. How to choose the suitable power for my Huaquan silent generator?

When selecting Huaquan silent generator sets, it is recommended to follow the steps below:

bướcconsiderationsSpecific suggestions
1Total load calculationList and add up the power of all devices that require simultaneous power supply
2Starting current reservationThe starting current of motor-driven equipment (air conditioners/water pumps) là 3-5 times the rated current
3biên độ an toànThe main power of the unit is ≥ 1.2 times the total load
4Noise limit assessmentConfirm the daytime/nighttime noise standards for the installation site
5Confirmation of installation locationThe silent unit only requires a flat floor and does not need to be installed in a machine room

Hint: Điện Hoa Tuyền provides a full range of silent generator sets from 15kW to 2000kW+, all utilizing our self-developed all-copper brushless motors and multiple noise reduction technologies. For detailed pricing or model selection advice, please contact Huaquan Power customer service.