Diesel generators operate in manual and automatic both modes to provide power supply when the main electrical source is unavailable. These modes control how the generators starts and stop. In diesel generator manual mode, the operator controls the generator while in automatic mode the power is supplied automatically when a main power fails. Understanding how to switch from manual to automatic and vice versa will assist in the efficient delivery of uninterrupted power supply while ensuring safety.
In thi article, we will walk you through the process of manual and automatic mode switching for diesel generators.
Overview of Operating Modes
Diesel generators mainly operate in two modes i.e. manual and automatic mode. Both are used for different purposes and utilised based on the level of automation required:
● Manual Mode
In manual mode the generator is controlled by the operator. They decide when to start or stop the generator. They also monitor the generator and connect and disconnect it based on the load requirements. Moreover, they are mostly used in maintenance, testing, and where human availability is needed.
● Automatic Mode
In diesel generator automatic mode, the generator does not need any operators. It constantly checks the main power supply and automatically starts operating when the power goes out.. The load is transferred automatically when the main power returns without human involvement. Moreover, it automatically shut down when it detects the main power is restored.
Components Involved in Mode Switching
There are various parts that work together in order to support the manual and automated switching from a diesel generator system.
1. Control Panel and Selector Switch
This is the primary interface used to operate the diesel generator. There is a selector switch in control panel which enable users to switch between manual and automatic modes. Operators use the control panel to start, stop, and monitor the generator during operation.
2. Automatic Transfer Switch (ATS)
ATS transfers the electrical load between the main supply and the generator. During power failure the load is automatically shifted to the generator. However, once the main power returns it safely transfers the load back.
3. Sensors and Control Relays
Sensors are responsible for monitoring voltage, frequency, and engine status. On the other hand, the control relays receive signals from these sensors and enable systems make correct decisions on when to start and stop the generator. These componets help the generator operate safely during mode switching.
● Manual Mode Switching Procedure
In this mode the operator directly control the diesel generators. However before switching to manual mode its important to make sure to consider few preconditions.
Preconditions Before Switching
Check the fuel, oil, and cooling system before you switch to manual mode. Make sure the load is disconnected properly and ready for manual control.
Step-by-Step Process to Switch to Manual Mode
- First, go to the generator control panel.
- Find the mode selector switch.
- Turn the switch from Automatic to Manual Mode.
- Once you switch to manual mode, check the display or indicator to confirm its active.
Note: Make sure the Automatic Transfer Switch (ATS) is not set to automatical before proceeding.
Starting and Stopping the Generator Manually
Press the manual start button to start the generator and give it some time to reach its stable state. Meanwhile continuously monitor its parameter such as speed and voltage and make sure they are stable too. Now, in order to stop the generator, the load should be disconnected first and then the stop button should be pressed. Allow it some time to shut it down completely.
● Automatic Mode Switching Procedure
In diesel generator automatic mode, the diesel generator can automatically start, stop, and provide power by itself in the presence of a power failure.
Preconditions Before Enabling Automatic Mode
Before switching to automatic mode check the fuel, oil, and coolant levels to make sure there are no warnings and problems. Ensure the ATS has been set to an automatic position and is ready for operation.
Steps of Automatic Generator Starting Sequence
Once a failure is detected in the power, the following processes are done automatically:
- The control panel sends the signal to turn on the generator.
- Automatic start of the generating engine
- It runs the generator until voltage and frequency stabilize.
Load Transfer Process in Automatic Mode
Once the generator become stable, the ATS automatically disconnects the load from the main supply and then connects it to the generator. The process make sure the connected equipements work contineuosly without getting interrupted.
Automatic Shutdown and Return to Mains Power
It automatically detects when the main power supply is restored. The ATS safely transfers the load back to the main power and stop the generator. The generator takes some time to cool down before it shut down completely.
● Switching Between Manual and Automatic Modes
To avoid any type of damage the switching between manual and automatic modes must be done carefully.
1. Safe Transition from Manual to Automatic Mode
Before you switch from manual to automatic, make sure the generator is not carrying any load and is in a stable condition. The steps involves:
- Stop the generator.
- Disconnect any load if connected with the generator.
- Switch from Manual to Automatic mode
- Once done, confirm automatic mode is active.
2. Safe Transition from Automatic to Manual Mode
Follow the given steps to safely switch from automatic to manual mode:
- Ensure the main power supply is stable or the generator is not required for backup.
- Switch the mode selector switch from Automatic to Manual.
- Confirm that the control panel is in manual mode. From this point on, the generator will accept only manually issued start and stop commands.
Conclusion
The proper choice of the operating mode is highly important for ensuring safe and smooth operation. Not only can safe switching be used for avoiding changes in load conditions, but it also avoids the chances of damage to the equipment. Switching between these two modes should be done carefully to protect your system components. With years of experience in power generation and energy solutions, Huaquan Power provides reliable solutions through advanced power equipment and power solutions.